New Yorker GHE-II Combi GHE2C-136B vs GHE2C-200

Verdict in brief

The GHE2C-136B and GHE2C-200 are the two GHE-II Combi sizes, both 95.0% AFUE with a 2-inch vent and the integrated hydro block. The 200 raises heating input from 13.6–120 to 20–150 MBH, DHW firing from 136 to 200 MBH and delivery from 3.7 to 5.2 GPM at a 70°F rise, in a deeper cabinet at 116 lb versus 95 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of New Yorker GHE-II Combi GHE2C-136B and New Yorker GHE-II Combi GHE2C-200
SpecificationNew Yorker GHE-II Combi GHE2C-136BNew Yorker GHE-II Combi GHE2C-200
Heating input, minimum13.6 MBH20 MBH
Heating input, maximum120 MBH150 MBH
DHW input, minimum13.6 MBH20 MBH
DHW input, maximum136 MBH200 MBH
DOE heating capacity113 MBH141 MBH
Net AHRI water rating98 MBH123 MBH
Efficiency (AFUE)95 %95 %
DHW rate at 70°F rise3.7 GPM5.2 GPM
DHW rate at 77°F rise3.4 GPM4.7 GPM
Vent and air intake2"2"
Boiler weight95 lb116 lb
Domestic hot waterIntegrated combi boiler: space heating plus on-demand domestic hot waterIntegrated combi boiler: space heating plus on-demand domestic hot water

What actually separates them

Both are condensing combi boilers with the same 316L stainless-steel boiler-side heat exchanger, flat-plate DHW heat exchanger, integrated three-way valve, pre-made primary/secondary manifold and 10:1 DHW turndown. Their rows both print 95.0% AFUE; the difference is reach on both sides of the appliance.

Space heating steps from 13.6–120 MBH input and 113 MBH DOE capacity on the 136B to 20–150 MBH and 141 MBH on the 200. The DHW side moves more: firing to 200 MBH instead of 136 and delivering 5.2 GPM instead of 3.7 GPM at a 70°F rise (4.7 vs 3.4 GPM at 77°F), which is the reason to choose the larger combi in households with larger or simultaneous draws.

Both models share the 2-inch direct-vent connection and the same control features; the 200 is 21 lb heavier and uses the deeper 20.4-inch cabinet. In a low-load home the 136B's lower 13.6 MBH minimum fire tracks shoulder-season demand more closely.

CurrentCanadian status unknown
Input
13.6–120 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II Combi GHE2C-136B is the smaller combi with 3.7 GPM DHW delivery at a 70°F rise: space heating at 13.6–120 MBH input with a DHW side firing 13.6–136 MBH at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II Combi GHE2C-200 is the larger combi with 5.2 GPM DHW delivery at a 70°F rise: space heating at 20–150 MBH input with a DHW side firing 20–200 MBH at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneCombi

Frequently asked questions

How much more hot water does the GHE2C-200 deliver?

5.2 GPM at a 70°F rise (4.7 at 77°F) against 3.7 GPM (3.4 at 77°F) on the GHE2C-136B, per the GHE-II data sheet.

Are both models the same size?

No — the 136B uses the 16.3-inch-deep cabinet at 95 lb and the 200 the 20.4-inch cabinet at 116 lb.

Which combi suits a smaller home?

The GHE2C-136B, because its lower 13.6 MBH minimum fire matches smaller heating loads while still firing to 136 MBH for domestic hot water.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.