New Yorker Boiler · GHE-II Combi
New Yorker GHE-II Combi GHE2C-136B
The New Yorker GHE-II Combi GHE2C-136B is the smaller combi with 3.7 GPM DHW delivery at a 70°F rise: space heating at 13.6–120 MBH input with a DHW side firing 13.6–136 MBH at 95.0% AFUE on the 316L stainless-steel condensing platform.
Key figures
- Max input
- 120 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 13.6 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
New Yorker GHE-II Combi GHE2C-136B in practice
The GHE-II Combi GHE2C-136B is a condensing combination boiler rated at 13.6–120 MBH heating input with a domestic hot water side firing 13.6–136 MBH. Its row in the GHE-II data sheet prints 113 MBH DOE heating capacity, a 98 MBH net AHRI water rating and 95.0% AFUE, with DHW delivery of 3.7 GPM at a 70°F rise (3.4 GPM at 77°F).
The combi platform adds an integrated hydro block system with a flat-plate heat exchanger, boiler circulator and three-way valve, a pre-made primary/secondary manifold with 1-1/4-inch sweat connections, DHW recirculation mode, DHW temperature maintained under all conditions and 10:1 DHW turndown. The boiler weighs 95 lb in a 16.3"-deep wall-hung cabinet and vents through a 2-inch direct-vent connection.
Boilers.ca documents this size at model level from the data sheet and links the published combi I&O manual. Gas, venting and electrical work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.
Best suited to
- 13.6-to-120 MBH residential heating loads
- Homes without space for a separate indirect water heater
- Households wanting DHW delivery around ${r.gpm70} GPM at a 70°F rise
Applicability and support
- Model number
- GHE2C-136B
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by New Yorker Boiler. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 13.6 MBH | Minimum heating input per the GHE-II data sheet combi ratings table. |
| Heating input, maximum | 120 MBH | Maximum heating input per the GHE-II data sheet combi ratings table. |
| DHW input, minimum | 13.6 MBH | Minimum domestic hot water input per the GHE-II data sheet combi ratings table. |
| DHW input, maximum | 136 MBH | Maximum domestic hot water input per the GHE-II data sheet combi ratings table. |
| Output | ||
| DOE heating capacity | 113 MBH | DOE heating capacity per the GHE-II data sheet combi ratings table. |
| Net AHRI water rating | 98 MBH | Net AHRI water rating per the GHE-II data sheet, based on a piping and pickup allowance of 1.15. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the GHE-II data sheet combi ratings table. |
| Domestic hot water | ||
| DHW rate at 70°F rise | 3.7 GPM | DHW rate at a 70°F rise per the GHE-II data sheet combi ratings table. |
| DHW rate at 77°F rise | 3.4 GPM | DHW rate at a 77°F rise per the GHE-II data sheet combi ratings table. |
| Domestic hot water | Integrated combi boiler: space heating plus on-demand domestic hot water | Integrated hydro block system with flat-plate heat exchanger, boiler circulator and 3-way valve; DHW recirculation mode, DHW temperature maintained under all conditions and 10:1 DHW turndown per the data sheet. |
| Venting and air | ||
| Vent and air intake | 2" | 2" vent and air-intake connection per the data sheet; combi models include a pre-made primary/secondary manifold. |
| Physical and connections | ||
| Boiler weight | 95 lb | Boiler weight per the GHE-II data sheet ratings table. |
| Boiler depth | 16.3" | Boiler depth per the GHE-II data sheet dimension table; the model is wall hung. |
| Operating limits and other | ||
| Fuel | Natural gas or LP gas (two-step conversion, no kit required) | The data sheet describes simple two-step LP conversion with no kit purchase required. |
| Control | Automatic no-touch combustion management with built-in self diagnostics | Control provides warm-weather shutdown and sensor-less rate-based reset; combi models use a Grundfos UPS-78 Special circulator. |
Manuals
Alerts documented for this model
Frequently asked questions
What are the GHE-II Combi GHE2C-136B's ratings?
13.6–120 MBH heating input, 113 MBH DOE heating capacity, 98 MBH net AHRI and 95.0% AFUE, with DHW firing to 136 MBH and 3.7 GPM at a 70°F rise per the GHE-II data sheet.
Is the primary/secondary manifold included?
Yes — the data sheet lists a pre-made primary/secondary manifold as included with combi models.
Questions about the New Yorker GHE-II Combi GHE2C-136B?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- New Yorker Boiler — GHE-II Combi Boiler product page · accessed September 9, 2026
- GHE-II Data Sheet (PDF) · accessed September 9, 2026
- GHE-II Combi Boiler Installation and Operating Instructions (PDF) · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.