Skip to content
Boilers.caby ROMA Heating & Cooling

New Yorker Boiler · GHE-II Combi

New Yorker GHE-II Combi GHE2C-200

The New Yorker GHE-II Combi GHE2C-200 is the larger combi with 5.2 GPM DHW delivery at a 70°F rise: space heating at 20–150 MBH input with a DHW side firing 20–200 MBH at 95.0% AFUE on the 316L stainless-steel condensing platform.

CurrentCanadian status unknown

Key figures

Max input
150 MBH
Max CSA output
—
AFUE
95 %
Min input
20 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

New Yorker GHE-II Combi GHE2C-200 in practice

The GHE-II Combi GHE2C-200 is a condensing combination boiler rated at 20–150 MBH heating input with a domestic hot water side firing 20–200 MBH. Its row in the GHE-II data sheet prints 141 MBH DOE heating capacity, a 123 MBH net AHRI water rating and 95.0% AFUE, with DHW delivery of 5.2 GPM at a 70°F rise (4.7 GPM at 77°F).

The combi platform adds an integrated hydro block system with a flat-plate heat exchanger, boiler circulator and three-way valve, a pre-made primary/secondary manifold with 1-1/4-inch sweat connections, DHW recirculation mode, DHW temperature maintained under all conditions and 10:1 DHW turndown. The boiler weighs 116 lb in a 20.4"-deep wall-hung cabinet and vents through a 2-inch direct-vent connection.

Boilers.ca documents this size at model level from the data sheet and links the published combi I&O manual. Gas, venting and electrical work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 20-to-150 MBH residential heating loads
  • Homes without space for a separate indirect water heater
  • Households wanting DHW delivery around ${r.gpm70} GPM at a 70°F rise

Applicability and support

Model number
GHE2C-200
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by New Yorker Boiler. Units are shown with every value; notes flag conflicting sources or missing figures.

New Yorker GHE-II Combi GHE2C-200 specifications
SpecificationValueNote
Input
Heating input, minimum20 MBHMinimum heating input per the GHE-II data sheet combi ratings table.
Heating input, maximum150 MBHMaximum heating input per the GHE-II data sheet combi ratings table.
DHW input, minimum20 MBHMinimum domestic hot water input per the GHE-II data sheet combi ratings table.
DHW input, maximum200 MBHMaximum domestic hot water input per the GHE-II data sheet combi ratings table.
Output
DOE heating capacity141 MBHDOE heating capacity per the GHE-II data sheet combi ratings table.
Net AHRI water rating123 MBHNet AHRI water rating per the GHE-II data sheet, based on a piping and pickup allowance of 1.15.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE per the GHE-II data sheet combi ratings table.
Domestic hot water
DHW rate at 70°F rise5.2 GPMDHW rate at a 70°F rise per the GHE-II data sheet combi ratings table.
DHW rate at 77°F rise4.7 GPMDHW rate at a 77°F rise per the GHE-II data sheet combi ratings table.
Domestic hot waterIntegrated combi boiler: space heating plus on-demand domestic hot waterIntegrated hydro block system with flat-plate heat exchanger, boiler circulator and 3-way valve; DHW recirculation mode, DHW temperature maintained under all conditions and 10:1 DHW turndown per the data sheet.
Venting and air
Vent and air intake2"2" vent and air-intake connection per the data sheet; combi models include a pre-made primary/secondary manifold.
Physical and connections
Boiler weight116 lbBoiler weight per the GHE-II data sheet ratings table.
Boiler depth20.4"Boiler depth per the GHE-II data sheet dimension table; the model is wall hung.
Operating limits and other
FuelNatural gas or LP gas (two-step conversion, no kit required)The data sheet describes simple two-step LP conversion with no kit purchase required.
ControlAutomatic no-touch combustion management with built-in self diagnosticsControl provides warm-weather shutdown and sensor-less rate-based reset; combi models use a Grundfos UPS-78 Special circulator.

Frequently asked questions

What are the GHE-II Combi GHE2C-200's ratings?

20–150 MBH heating input, 141 MBH DOE heating capacity, 123 MBH net AHRI and 95.0% AFUE, with DHW firing to 200 MBH and 5.2 GPM at a 70°F rise per the GHE-II data sheet.

Is the primary/secondary manifold included?

Yes — the data sheet lists a pre-made primary/secondary manifold as included with combi models.

Questions about the New Yorker GHE-II Combi GHE2C-200?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate