NTI Trinity FTVN110 vs FTVN150

Verdict in brief

The FTVN110 and FTVN150 are both 95% AFUE heating-only FTVN boilers, and the 150 buys 40 MBH of ceiling (150 vs 110 MBH) at the cost of 15 lb more weight and a minimum fire that rises from 11 to 15 MBH. Both keep the same connections and the 2" venting option, so the heat-loss calculation decides.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity FTVN110 and NTI Trinity FTVN150
SpecificationNTI Trinity FTVN110NTI Trinity FTVN150
Input, minimum11 MBH15 MBH
Input, maximum110 MBH150 MBH
Efficiency (AFUE)95 %95 %
Turndown ratioup to 10:1up to 10:1
Weight107 lb122 lb
Max. equivalent vent length, 2"100 ft100 ft
Max. equivalent vent length, 3"150 ft150 ft
CH water connections1 1/4" NPT1 1/4" NPT
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both models run the same FTVN platform at 95% AFUE with 1 1/4" NPT CH connections, 3/4" NPT gas and identical venting options — 2" to 100 ft or 3" to 150 ft per side. The published differences are input range and weight: 11 to 110 MBH at 107 lb for the 110, 15 to 150 MBH at 122 lb for the 150.

The minimum fire steps from 11 to 15 MBH between the two models, which is modest but real: in a home whose load sits near the 110's ceiling, the 150 can still modulate acceptably, while in a small low-load house the 110 tracks mild weather better.

Neither boiler produces domestic hot water, so the indirect tank or separate water heater is common to both. The 150 is justified when the heat-loss calculation plus recovery demand genuinely exceeds 110 MBH; below that, the lighter 110 delivers the same condensing technology at a lower minimum fire.

CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The NTI Trinity FTVN110 is the 95% AFUE mid-size heating-only member of the FTVN wall-hung family, firing 11 to 110 MBH in the same 107 lb cabinet as the FTVN085, with 2" venting to 100 ft or 3" to 150 ft per side.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
95 %

The NTI Trinity FTVN150 is the 95% AFUE heating-only FTVN for homes between the 110 and 199 sizes: it fires 15 to 150 MBH, weighs 122 lb, and keeps 2" venting to 100 ft or 3" to 150 ft per side.

Natural gasPropaneHeating-only

Frequently asked questions

What does the FTVN150 add over the FTVN110?

Input rises from 110 to 150 MBH, but weight rises from 107 to 122 lb and the minimum fire from 11 to 15 MBH. AFUE, connections and venting are unchanged at 95%.

Do both models allow 2" venting?

Yes — both vent in 2" pipe to 100 ft or 3" pipe to 150 ft per side, with no 199-model restriction on either.

When is the FTVN150 the right choice?

When the room-by-room heat-loss calculation plus indirect-tank demand exceeds 110 MBH. Sizing beyond the calculated load reduces steady condensing time in mild weather.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.