NTI Trinity FTVN150 vs FTVN199

Verdict in brief

The FTVN150 and FTVN199 are the two largest heating-only FTVN models, both rated 95% AFUE with the same connections. The 199 adds 49 MBH of ceiling and weighs 17.5 lb more, but its minimum fire rises to 19.9 MBH and its 2" venting terms follow NTI technical bulletin 2022-10-26, so 3" venting is the planning figure.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity FTVN150 and NTI Trinity FTVN199
SpecificationNTI Trinity FTVN150NTI Trinity FTVN199
Input, minimum15 MBH19.9 MBH
Input, maximum150 MBH199 MBH
Efficiency (AFUE)95 %95 %
Turndown ratioup to 10:1up to 10:1
Weight122 lb139.5 lb
Max. equivalent vent length, 2"100 ft100 ft
Max. equivalent vent length, 3"150 ft150 ft
CH water connections1 1/4" NPT1 1/4" NPT
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both boilers are heating-only FTVN models at 95% AFUE with 1 1/4" NPT CH connections and 3/4" NPT gas. The 150 fires 15 to 150 MBH at 122 lb; the 199 fires 19.9 to 199 MBH at 139.5 lb, giving the larger model roughly a third more ceiling for its 17.5 lb of extra weight.

The minimum fire rises from 15 to 19.9 MBH between them, and the 199's 2" venting terms follow NTI technical bulletin 2022-10-26 even though the manual prints 2" runs to 100 ft. Most 199 installations are therefore planned on 3" pipe to the 150 ft per-side limit, which makes the vent route part of the model decision.

Since neither model heats domestic water, hot-water load is handled identically with an indirect tank or separate water heater. The 199 earns its place when the heat-loss calculation plus recovery demand approaches 199 MBH — large homes or small multi-suite buildings — while houses that fit within 150 MBH keep the lower minimum fire and unrestricted 2" option of the 150.

CurrentSold in Canada
Input
15–150 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity FTVN150 is the 95% AFUE heating-only FTVN for homes between the 110 and 199 sizes: it fires 15 to 150 MBH, weighs 122 lb, and keeps 2" venting to 100 ft or 3" to 150 ft per side.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity FTVN199 is the largest heating-only FTVN: 19.9 to 199 MBH input at 95% AFUE in a 139.5 lb wall-hung boiler. Its 2" venting terms follow NTI technical bulletin 2022-10-26, so most installations run 3" to the 150 ft limit.

Natural gasPropaneHeating-only

Frequently asked questions

Can the FTVN199 be vented in 2" pipe?

The I&O manual lists 2" to 100 ft, but the 2" terms on the 199 models follow NTI technical bulletin 2022-10-26, so plan the installation on 3" venting to 150 ft per side.

Is the FTVN199 too large for a typical house?

Usually. Its 19.9 MBH minimum fire is the highest in the FTVN line, so a house whose load fits within 150 MBH will cycle more on a 199; the heat-loss calculation should approach the larger model's range before choosing it.

How much heavier is the FTVN199?

139.5 lb versus 122 lb for the FTVN150, per NTI's product table — about 17.5 lb more for 49 MBH of extra input ceiling.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate