NTI Trinity FTVN199

The NTI Trinity FTVN199 is the largest heating-only FTVN: 19.9 to 199 MBH input at 95% AFUE in a 139.5 lb wall-hung boiler. Its 2" venting terms follow NTI technical bulletin 2022-10-26, so most installations run 3" to the 150 ft limit.

CurrentSold in Canada

Key figures

Max input
199 MBH
Max CSA output
AFUE
95 %
Min input
19.9 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

NTI Trinity FTVN199 in practice

The FTVN199 tops the FTVN family at 199 MBH input for large homes and small multi-suite buildings, with the highest minimum fire in the series at 19.9 MBH. It is heating-only, weighs 139.5 lb, and connects on the same 1 1/4" NPT CH and 3/4" NPT gas connections as the rest of the line.

Venting needs an early planning check: the I&O manual allows 2" to 100 ft and 3" to 150 ft, but the 2" terms on the 199 models follow NTI technical bulletin 2022-10-26, so a 199 installation should be planned on 3" pipe within 150 ft per side. In BC's climate the 19.9 MBH minimum also argues against oversizing: a home whose heat-loss calculation sits well under this boiler's range will spend more time at minimum fire, so the FTVN150 is often the better match for mid-size houses.

Best suited to

  • Large homes and small multi-suite buildings needing up to 199 MBH of input
  • Projects where one wall-hung FTVN replaces a bigger older boiler
  • Mechanical rooms within 150 ft of a vent terminal where 3" piping can be run

Applicability and support

Model number
FTVN199
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

NTI Trinity FTVN199 specifications
SpecificationValueNote
Input
Input, minimum19.9 MBHPer the NTI product page.
Input, maximum199 MBHPer the NTI product page.
Efficiency
Efficiency (AFUE)95 %DOE AFUE per the NTI product page; only the FTVN085 is rated 96%.
Domestic hot water
Domestic hot waterHeating-only; pair with an indirect tank or separate water heater
Venting and air
Max. equivalent vent length, 2"100 ftEach side per the I&O manual; the 2" terms on this model follow NTI technical bulletin 2022-10-26.
Max. equivalent vent length, 3"150 ftEach side per the I&O manual.
Physical and connections
Weight139.5 lbPer the NTI product page.
CH water connections1 1/4" NPTPer the NTI product page.
Gas connection3/4" NPTMale NPT per the NTI product page.
Operating limits and other
FuelNatural gas or propaneNTI publishes LP conversion instructions for this series.
Turndown ratioup to 10:1Manufacturer marketing figure on the NTI product page.

Frequently asked questions

Can the FTVN199 vent in 2" pipe?

The I&O manual lists 2" runs to 100 ft and 3" runs to 150 ft, but the 2" terms on the 199 models follow NTI technical bulletin 2022-10-26, so plan the installation on 3" venting.

Is the FTVN199 suitable for my house?

Only a heat-loss calculation can say. The boiler fires down to a 19.9 MBH minimum, so in a home whose load is far below 199 MBH the larger minimum fire reduces steady condensing operation; the FTVN150 or FTVN110 may serve better.

How heavy is the FTVN199?

139.5 lb per the NTI product page — the heaviest heating-only FTVN, and about 17.5 lb more than the FTVN150.

Questions about the NTI Trinity FTVN199?