NTI GF 200 vs GF150

Verdict in brief

The GF 200 and GF150 are the two Green Furnace combi-furnace sizes: the GF 200 spans 19,900-199,000 BTU/hr DHW input at 97% AFUE with up to 7.8 gpm at a 50°F rise, while the GF150 spans 13,200-150,000 BTU/hr at 95% AFUE with 3.6 gpm at a 77°F rise and up to 3 tons of cooling.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI GF 200 and NTI GF150
SpecificationNTI GF 200NTI GF150
DHW input, maximum199 MBH150 MBH
Efficiency (AFUE)97 %95 %
Max DHW flow at 77°F rise3.6 GPM
DHW flow at 80°F rise4.8 GPM
VentingForced draft direct vent, 2" or 3"2" (0-100 ft intake / 6-100 ft exhaust) or 3" (0-150 ft intake / 6-150 ft exhaust)
Gas inlet3/4" NPT3/4" NPT-M

What actually separates them

The GF200 submittal lists space-heating input of 19,900-80,000 BTU/hr and DHW input of 19,900-199,000 BTU/hr with 97% AFUE and a 0.97 energy factor; the GF150 spec table lists 13,200-120,000 BTU/hr space heating and 13,200-150,000 BTU/hr DHW with 95% AFUE.

Domestic hot water delivery is printed on different bases: the GF 200's flow table gives 7.8 gpm at a 50°F rise, 6.0 gpm at 65°F and 4.8 gpm at 80°F, while the GF150 prints 3.6 gpm at a 77°F rise.

The GF150 adds cooling capability up to 3 tons with 360-1200 CFM cooling airflow, while both share forced-draft direct venting in 2" or 3" pipe and 3/4" gas connections.

NTI Boilers

NTI GF 200

CurrentSold in Canada
Input
19.9–80 MBH
Output (max)
AFUE
97 %

The NTI GF 200 is a combi-furnace with 19,900-80,000 BTU/hr space-heating input, 19,900-199,000 BTU/hr DHW input, 97% AFUE and a 0.97 DHW energy factor, delivering up to 7.8 gpm at a 50°F rise from an internal recirculation and buffer tank.

Natural gasPropaneCombi

NTI Boilers

NTI GF150

CurrentSold in Canada
Input
13.2–80 MBH
Output (max)
AFUE
95 %

The NTI GF150 is a combi-furnace with 13,200-120,000 BTU/hr space-heating capacity, 13,200-150,000 BTU/hr DHW capacity, 95% AFUE, up to 3 tons of cooling and 3.6 gpm of domestic hot water at a 77°F rise.

Natural gasPropaneCombi

Frequently asked questions

Which Green Furnace is more efficient?

The GF 200 prints 97% AFUE and a 0.97 DHW energy factor; the GF150 prints 95% AFUE.

Which model provides air conditioning?

The GF150's spec table lists cooling capacity up to 3 tons with 360-1200 CFM cooling airflow; the GF200 submittal is printed around heating and DHW capacity.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.