NTI Boilers · Green Furnace (GF200 / GF150)
NTI GF150
The NTI GF150 is a combi-furnace with 13,200-120,000 BTU/hr space-heating capacity, 13,200-150,000 BTU/hr DHW capacity, 95% AFUE, up to 3 tons of cooling and 3.6 gpm of domestic hot water at a 77°F rise.
Key figures
- Max input
- 80 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 13.2 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI GF150 in practice
The GF150 merges NTI's TRX combi boiler with a high-efficiency air handler to provide forced-air heating, domestic hot water and hydronic capability from one unit. The product-page specification table prints forced-air heating capacity of 13,200-80,000 BTU/hr, combined hydronic and forced-air space heating of 13,200-120,000 BTU/hr, DHW capacity of 13,200-150,000 BTU/hr, 95% AFUE, up to 3 tons of cooling, 300-1200 CFM heating airflow and 360-1200 CFM cooling airflow, with a maximum DHW flow of 3.6 gpm at a 77°F rise.
Connections are 3/4" NPT-M for DHW, CH supply/return and gas, and venting is 2" or 3" direct vent with intake runs to 100-150 ft and exhaust runs of 6-150 ft. NTI lists a built-in expansion tank sufficient for installs without hydronic loops, a built-in manual fill valve, and reversible left/right DHW and gas connections; the GF150 submittal prints a 111 MBH heating output and a 97 MBH net AHRI rating, and the model is field-convertible to LP gas with LP pressures of 8-13" W.C.
Best suited to
- Homes that want cooling, forced-air heating and domestic hot water from one cabinet
- Retrofits replacing a mid-size furnace and water heater
- Installations that need reversible DHW and gas connections for layout flexibility
Applicability and support
- Model number
- GF150
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Forced-air heating capacity, minimum | 13.2 MBH | Per the GF150 product-page specification table. |
| Forced-air heating capacity, maximum | 80 MBH | Per the GF150 product-page specification table. |
| Space heating capacity (hydronic + forced air), maximum | 120 MBH | Per the GF150 product-page specification table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | Per the GF150 product-page specification table and submittal. |
| Domestic hot water | ||
| DHW capacity, maximum | 150 MBH | Per the GF150 product-page specification table. |
| Max DHW flow at 77°F rise | 3.6 GPM | Per the GF150 product-page specification table and submittal. |
| DHW inlet / outlet | 3/4" NPT-M | Per the GF150 product-page specification table. |
| Venting and air | ||
| Venting | 2" (0-100 ft intake / 6-100 ft exhaust) or 3" (0-150 ft intake / 6-150 ft exhaust) | Per the GF150 product-page specification table. |
| Physical and connections | ||
| Gas connection | 3/4" NPT-M | Per the GF150 product-page specification table. |
| CH supply / return | 3/4" NPT-M | Per the GF150 product-page specification table. |
| Operating limits and other | ||
| Cooling capacity | Up to 3 tons | Per the GF150 product-page specification table. |
| Heating airflow | 300-1200 CFM | Per the GF150 product-page specification table. |
| Cooling airflow | 360-1200 CFM | Per the GF150 product-page specification table. |
| Gas pressure | NG 3.5-10.5" W.C.; LP 8-13" W.C. | Per the GF150 product-page specification table. |
Manuals
Alerts documented for this model
None documented yet.
Frequently asked questions
What are the GF150's capacities?
The spec table prints 13,200-80,000 BTU/hr forced-air heating, 13,200-120,000 BTU/hr combined space heating, 13,200-150,000 BTU/hr DHW and up to 3 tons of cooling, with 95% AFUE and 3.6 gpm DHW at a 77°F rise.
Does the GF150 provide air conditioning?
The unit supports cooling up to 3 tons with 360-1200 CFM cooling airflow per the product-page specification table; the air handler section handles the cooling coil.
What is the GF150's heating output?
The GF150 submittal prints a 111 MBH heating output capacity and a 97 MBH net AHRI rating.
Questions about the NTI GF150?
Describe what the boiler is doing and get a straight answer about the next step.