NTI GF 200

The NTI GF 200 is a combi-furnace with 19,900-80,000 BTU/hr space-heating input, 19,900-199,000 BTU/hr DHW input, 97% AFUE and a 0.97 DHW energy factor, delivering up to 7.8 gpm at a 50°F rise from an internal recirculation and buffer tank.

CurrentSold in Canada

Key figures

Max input
80 MBH
Max CSA output
—
AFUE
97 %
Min input
19.9 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

NTI GF 200 in practice

The GF 200 merges NTI's condensing combi platform with an ECM air handler to provide forced-air heating, hydronic heating and domestic hot water from one appliance. The submittal model specifications table prints space-heating input of 19,900-80,000 BTU/hr, DHW input of 19,900-199,000 BTU/hr, 97% AFUE, a 0.97 energy factor on domestic water and DHW flow rates of 7.8 gpm at a 50°F rise, 6.0 gpm at 65°F and 4.8 gpm at 80°F.

The unit stands 38" high in a 17.75" x 38" footprint and weighs 248 lb, with forced-draft direct venting in 2" or 3" pipe, 15-150 PSI water pressure, a 3/4" NPT gas inlet and 3/4" female sweat DHW connections. NTI's feature list includes the internal recirculation and buffer tank that eliminates the cold-water sandwich, simultaneous DHW and space heating, a DEC Star ECM blower that adjusts to static pressure, a shaftless blower, a negative-pressure gas valve and premix burner modulating across the DHW range, and field conversion to LP gas.

Best suited to

  • Homes replacing a furnace and water heater with one appliance
  • Households that want forced-air heating plus domestic hot water and hydronic capability
  • Installations where the internal buffer tank removes the need for a separate storage tank

Applicability and support

Model number
GF 200
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

NTI GF 200 specifications
SpecificationValueNote
Input
Space heating input, minimum19.9 MBHPer the GF200 submittal model specifications table.
Space heating input, maximum80 MBHPer the GF200 submittal model specifications table.
Efficiency
Efficiency (AFUE)97 %The submittal prints 97% AFUE for NG and LP and notes the rating is based on NTI lab testing sent to AHRI.
Energy factor (DHW)0.97Per the GF200 submittal model specifications table.
Domestic hot water
DHW input, minimum19.9 MBHPer the GF200 submittal model specifications table.
DHW input, maximum199 MBHPer the GF200 submittal model specifications table.
DHW flow at 50°F rise7.8 GPMPer the submittal's flow-rate table.
DHW flow at 65°F rise6 GPMPer the submittal's flow-rate table.
DHW flow at 80°F rise4.8 GPMPer the submittal's flow-rate table.
DHW inlet / outlet3/4" female sweatPer the GF200 submittal.
Venting and air
VentingForced draft direct vent, 2" or 3"Per the GF200 submittal.
Physical and connections
Weight248 lbPer the GF200 submittal.
Dimensions17.75" W x 38.0" H x 38.0" DPer the GF200 submittal.
Gas inlet3/4" NPTPer the GF200 submittal.
Operating limits and other
Water pressure15-150 PSIPer the GF200 submittal.

Frequently asked questions

What are the GF 200's capacities?

The submittal lists 19,900-80,000 BTU/hr space-heating input and 19,900-199,000 BTU/hr DHW input, with 97% AFUE, a 0.97 DHW energy factor and flow rates up to 7.8 gpm at a 50°F rise.

Does the GF 200 need a separate water heater?

No. It produces domestic hot water through its combi section with an internal recirculation and buffer tank, while also providing forced-air and hydronic space heating.

What venting does the GF 200 use?

Forced-draft direct vent in 2" or 3" pipe, per the GF200 submittal.

Questions about the NTI GF 200?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate