NTI Compass NC150 vs NC199

Verdict in brief

The Compass NC150 and NC199 are the two largest heating-only Compass models, both 95% AFUE on the same floor platform with identical connections and venting. The NC199 fires to 199 MBH instead of 150 at 214 lb instead of 203 lb, and its minimum fire rises from 15 to 19.9 MBH — the price of a 199-class ceiling in a floor cabinet.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Compass NC150 and NTI Compass NC199
SpecificationNTI Compass NC150NTI Compass NC199
Input, minimum15 MBH19.9 MBH
Input, maximum150 MBH199 MBH
Efficiency (AFUE)95 %95 %
Turndown ratioup to 10:1up to 10:1
Weight203 lb214 lb
Max. equivalent vent length, 2"100 ft100 ft
Max. equivalent vent length, 3"150 ft150 ft
CH water connections1 1/4" NPT1 1/4" NPT
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both models run the Compass floor platform at 95% AFUE with 1 1/4" NPT CH connections, 3/4" NPT gas and identical 2" (100 ft) / 3" (150 ft) venting terms. The NC150 fires 15 to 150 MBH at 203 lb; the NC199 fires 19.9 to 199 MBH at 214 lb.

The 199 adds 49 MBH of ceiling for 11 lb of extra cabinet weight, but its minimum fire is 4.9 MBH higher than the 150's. In a house whose load sits well under 150 MBH, the larger boiler spends more time near its minimum rather than modulating steadily — the classic oversizing penalty.

Both are heating-only with domestic hot water from an indirect tank or separate water heater. The NC199 earns its place when the heat-loss calculation plus recovery demand approaches 199 MBH — large homes where a floor-footprint 199 beats a wall-hung installation — while loads within 150 MBH stay on the NC150.

CurrentSold in Canada
Input
15–150 MBH
Output (max)
—
AFUE
95 %

The NTI Compass NC150 is the 95% AFUE floor-standing Compass for mid-to-larger homes: 15 to 150 MBH input in a 203 lb floor cabinet with the platform's reversible connections and integrated pump package.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
—
AFUE
95 %

The NTI Compass NC199 is the largest heating-only Compass: 19.9 to 199 MBH input at 95% AFUE in a 214 lb floor cabinet — the floor-standing option for large homes that would otherwise need a wall-hung 199.

Natural gasPropaneHeating-only

Frequently asked questions

How does the NC199 differ from the NC150?

Input rises from 150 to 199 MBH and weight from 203 to 214 lb; both are heating-only at 95% AFUE with the same connections and venting.

Is the NC199's minimum fire much higher?

Yes — 19.9 MBH against 15 MBH on the NC150, which matters for low-load houses that would spend long periods at minimum fire on the 199.

When is the NC199 the right Compass?

When the heat-loss calculation plus hot-water recovery genuinely approaches 199 MBH. It is the floor-footprint way to get a 199-class input without a wall-hung installation.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.