NTI Compass NC150
The NTI Compass NC150 is the 95% AFUE floor-standing Compass for mid-to-larger homes: 15 to 150 MBH input in a 203 lb floor cabinet with the platform's reversible connections and integrated pump package.
Key figures
- Max input
- 150 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 15 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI Compass NC150 in practice
The NC150 takes the Compass to a 150 MBH ceiling at 95% AFUE, adding 10 lb over the 193 lb NC085 and NC110 cabinets. It is heating-only, connects on 1 1/4" NPT CH pipe with 3/4" NPT gas, and retains the stainless fire-tube heat exchanger, brass internals, ECM pump and primary/secondary piping that define the platform.
The 150 is the natural floor-standing stop for a typical larger BC detached home: more ceiling than the 110 for radiators, in-floor loops or indirect-tank recovery, without the 199's higher 19.9 MBH minimum fire. As with every Compass, the vent route runs in 2" to 100 ft or 3" to 150 ft per side.
Best suited to
- Mid-to-larger detached homes needing between 110 and 150 MBH
- Floor-footprint replacements where the existing piping layout is retained
- Homes pairing a floor-standing boiler with an indirect tank
Applicability and support
- Model number
- NC150
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 15 MBH | Per the NTI product page. |
| Input, maximum | 150 MBH | Per the NTI product page. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | DOE AFUE per the NTI product page. |
| Domestic hot water | ||
| Domestic hot water | Heating-only; pair with an indirect tank or separate water heater | |
| Venting and air | ||
| Max. equivalent vent length, 2" | 100 ft | Each side per the I&O manual. |
| Max. equivalent vent length, 3" | 150 ft | Each side per the I&O manual. |
| Physical and connections | ||
| Weight | 203 lb | Per the NTI product page. |
| CH water connections | 1 1/4" NPT | Male NPT per the NTI product page. |
| Gas connection | 3/4" NPT | Male NPT per the NTI product page. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | NTI publishes LP conversion instructions for this series. |
| Turndown ratio | up to 10:1 | Manufacturer marketing figure on the NTI product page. |
Manuals
- Compass I&O Manual, 420011304100, Rev 04 (20240404)420011304100 Rev 04 · 2024-04-04
Alerts documented for this model
Frequently asked questions
How heavy is the NC150?
203 lb per the NTI product page, against 193 lb for the NC085 and NC110 and 214 lb for the NC199.
Is the NC150 more efficient than the NC085?
No. NTI rates the NC150 at 95% AFUE; the NC085 is the only Compass model rated 96%.
Can the NC150's piping go either direction?
Yes. NTI markets the Compass with left- or right-hand piping connections, which is one of its retrofit advantages over fixed-layout boilers.
Questions about the NTI Compass NC150?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- NTI — NTI Compass Series product page · accessed September 7, 2026
- Compass I&O Manual, 420011304100, Rev 04 (20240404) · 420011304100 Rev 04 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.