Skip to content
Boilers.caby ROMA Heating & Cooling

NTI Boilers · NTI Compass

NTI Compass NC199

The NTI Compass NC199 is the largest heating-only Compass: 19.9 to 199 MBH input at 95% AFUE in a 214 lb floor cabinet — the floor-standing option for large homes that would otherwise need a wall-hung 199.

CurrentSold in Canada

Key figures

Max input
199 MBH
Max CSA output
—
AFUE
95 %
Min input
19.9 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

NTI Compass NC199 in practice

The NC199 tops the heating-only Compass range at 199 MBH input and 95% AFUE in the platform's 214 lb floor cabinet. It keeps the reversible connections, integrated ECM pump and primary/secondary piping of the smaller models, and its 1 1/4" NPT CH connections and 3/4" NPT gas connection match the rest of the series.

Because the whole Compass line shares one floor footprint logic, the NC199 is the straightforward choice when the heat-loss calculation plus indirect-tank demand approaches 199 MBH but a wall-hung installation is not wanted. Its 19.9 MBH minimum fire is the highest in the heating-only Compass line, so sizing must come from the calculation rather than from reserve thinking.

Best suited to

  • Large homes with high heat-loss and recovery demand up to 199 MBH
  • Projects replacing a floor-mounted boiler in the 199 MBH class
  • Homes preferring the Compass floor footprint over wall-hung mounting

Applicability and support

Model number
NC199
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

NTI Compass NC199 specifications
SpecificationValueNote
Input
Input, minimum19.9 MBHPer the NTI product page.
Input, maximum199 MBHPer the NTI product page.
Efficiency
Efficiency (AFUE)95 %DOE AFUE per the NTI product page.
Domestic hot water
Domestic hot waterHeating-only; pair with an indirect tank or separate water heater
Venting and air
Max. equivalent vent length, 2"100 ftEach side per the I&O manual.
Max. equivalent vent length, 3"150 ftEach side per the I&O manual.
Physical and connections
Weight214 lbPer the NTI product page.
CH water connections1 1/4" NPTMale NPT per the NTI product page.
Gas connection3/4" NPTMale NPT per the NTI product page.
Operating limits and other
FuelNatural gas or propaneNTI publishes LP conversion instructions for this series.
Turndown ratioup to 10:1Manufacturer marketing figure on the NTI product page.

Frequently asked questions

What is the difference between the NC199 and the NC150?

Input rises from 150 to 199 MBH and weight from 203 to 214 lb; both are heating-only at 95% AFUE with the same connections. The NC199's minimum fire is 19.9 MBH against 15 MBH.

Is the Compass NC199 a combi?

No. For domestic hot water from a single appliance, the Compass combis are the NC110C, NC150C and NC199C.

Does the NC199 need special venting?

No — like the rest of the Compass line it vents in 2" pipe to 100 ft or 3" to 150 ft per side, with no 199-model restriction printed on the Compass page.

Questions about the NTI Compass NC199?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate