NTI Trinity TFTN150 vs TFTN199

Verdict in brief

The TFTN150 and TFTN199 are the two largest TFTN wall models in the compact cabinet class: both 95% AFUE, both 19 7/8 by 34 1/8 by 18 3/4 inches, with the same connections and venting. The 199 fires to 199 MBH instead of 150 but its minimum fire rises to 19.9 MBH and it weighs 140 lb against 122 lb with water.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity TFTN150 and NTI Trinity TFTN199
SpecificationNTI Trinity TFTN150NTI Trinity TFTN199
Input, minimum15 MBH19.9 MBH
Input, maximum150 MBH199 MBH
Efficiency (AFUE)95 %95 %
Weight122 lb140 lb
Width19.875 in19.875 in
Height34.125 in34.125 in
Depth18.75 in18.75 in
Max. equivalent vent length, 2"100 ft100 ft
Max. equivalent vent length150 ft150 ft
CH water connections1 1/4" NPT1 1/4" NPT
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

The 150 and 199 share the compact TFTN cabinet exactly — 19 7/8 inches wide, 34 1/8 inches high, 18 3/4 inches deep — with the same 1 1/4" NPT CH connections, 3/4" NPT gas and 2" (100 ft) / 3" (150 ft) venting terms. Both are rated 95% AFUE and heating-only.

The differences are range and weight: the 150 fires 15 to 150 MBH at 122 lb with water, and the 199 fires 19.9 to 199 MBH at 140 lb. The 199's 18 lb penalty buys 49 MBH of ceiling, but its minimum fire is 4.9 MBH higher, which shortens steady condensing in homes whose load sits well below 199 MBH.

Since the cabinet is identical, there is no installation difference to weigh — only the calculated load. A home or small multi-suite building whose heat-loss plus recovery demand approaches 199 MBH justifies the 199; loads that fit within 150 MBH keep the lighter 150 with its lower minimum fire.

CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
95 %

The NTI Trinity TFTN150 is the 95% AFUE wall-hung TFTN for mid-to-larger homes: 15 to 150 MBH input, 122 lb with water, on 1 1/4" NPT CH connections with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
AFUE
95 %

The NTI Trinity TFTN199 is the 95% AFUE wall-hung TFTN at the classic 199 MBH mark: 19.9 to 199 MBH input, 140 lb with water, still on 1 1/4" NPT CH connections with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only

Frequently asked questions

Are the TFTN150 and TFTN199 different sizes?

No. Both measure 19 7/8 by 34 1/8 by 18 3/4 inches; the 199 simply weighs more (140 lb against 122 lb with water) and fires higher.

Do both models have the same venting?

Yes — 2" to 100 ft or 3" to 150 ft per side on both, with no 199-model restriction printed on the TFTN page.

When is the TFTN199 the right call?

When the heat-loss calculation plus hot-water recovery demand more than the 150 can deliver on a design day. Extra ceiling without a matching load raises the minimum fire the boiler idles at in mild weather.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.