Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

NTI Trinity TFTN199 vs TFTN285

Verdict in brief

The TFTN199 and TFTN285 are both 95% AFUE heating-only TFTN wall models, and the 285 is the step out of the compact class: it fires 28.5 to 285 MBH in a wider 21 3/8 inch cabinet at 180 lb with water, loses the 2" venting option entirely, and raises the minimum fire from 19.9 to 28.5 MBH.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity TFTN199 and NTI Trinity TFTN285
SpecificationNTI Trinity TFTN199NTI Trinity TFTN285
Input, minimum19.9 MBH28.5 MBH
Input, maximum199 MBH285 MBH
Efficiency (AFUE)95 %95 %
Weight140 lb180 lb
Width19.875 in21.375 in
Height34.125 in34.125 in
Depth18.75 in18.375 in
Max. equivalent vent length150 ft150 ft
CH water connections1 1/4" NPT1 1/4" NPT
Gas connection3/4" NPT3/4" NPT
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

The 199 tops the compact TFTN class at 19.9 to 199 MBH in the 19 7/8 by 34 1/8 by 18 3/4 inch cabinet at 140 lb with water. The 285 moves up to a 21 3/8 inch-wide cabinet (34 1/8 inches high, 18 3/8 inches deep) at 180 lb with water, firing 28.5 to 285 MBH — both rated 95% AFUE with 1 1/4" NPT CH connections.

Venting is a hard difference: the 199 keeps the 2" option to 100 ft alongside 3" to 150 ft, while the TFTN285 is 3" only, to 150 ft per side. The minimum fire also jumps from 19.9 to 28.5 MBH, reflecting NTI's positioning of the 285-and-up sizes toward commercial applications.

Both are heating-only with domestic hot water handled externally. The 285 is the right stop when the heat-loss or plant-demand calculation exceeds 199 MBH and the mechanical room can run 3" venting within 150 ft; buildings that fit inside 199 MBH keep the lighter compact cabinet and the 2" venting option of the 199.

CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity TFTN199 is the 95% AFUE wall-hung TFTN at the classic 199 MBH mark: 19.9 to 199 MBH input, 140 lb with water, still on 1 1/4" NPT CH connections with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
28.5–285 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity TFTN285 is the 95% AFUE wall-hung TFTN for big houses and light-commercial plants: 28.5 to 285 MBH input, 180 lb with water, in a wider 21 3/8 inch cabinet with 3"-only venting to 150 ft.

Natural gasPropaneHeating-only

Frequently asked questions

Can the TFTN285 vent in 2" pipe?

No. NTI lists 3" venting only for the TFTN285, to 150 ft maximum each side; the 2" option ends with the TFTN199.

Is the TFTN285 wider than the 199?

Yes — 21 3/8 inches against 19 7/8 inches, and 180 lb with water against 140 lb. Both stand 34 1/8 inches high.

Is the TFTN285 a commercial boiler?

NTI says the 285-to-850 sizes are available for commercial applications; the 285 is the smallest of that larger-input class, so it fits big residential and light-commercial loads alike.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate