NTI Trinity TFTN725 vs TFTN850

Verdict in brief

The TFTN725 and TFTN850 are the two largest floor-mounted TFTN models and share the same connection and venting class: 2 1/2" water, 1 1/4" gas and 6" venting. The 850 fires 85 to 850 MBH instead of 72.5 to 725 MBH, lifting heating capacity from 705 to 825 MBH and the Net AHRI rating from 613 to 717 MBH for only 5 lb more weight (690 lb against 685 lb with water).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity TFTN725 and NTI Trinity TFTN850
SpecificationNTI Trinity TFTN725NTI Trinity TFTN850
Input, minimum72.5 MBH85 MBH
Input, maximum725 MBH850 MBH
Thermal efficiency97.7 %97.6 %
Heating capacity705 MBH825 MBH
Net AHRI rating613 MBH717 MBH
Weight685 lb690 lb
Water content17.5 gal16.5 gal
CH water connections2 1/2" NPT2 1/2" NPT
Gas connection1 1/4" NPT1 1/4" NPT
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both models sit on the same TFTN floor class: 2 1/2" male NPT water connections, a 1 1/4" male NPT gas connection and 6" venting to 150 ft per side. NTI lists the 725 at 72.5 to 725 MBH input and 97.7% thermal efficiency, and the 850 at 85 to 850 MBH input and 97.6% thermal efficiency — a tenth of a point apart.

The 850 delivers an 825 MBH heating capacity and a 717 MBH Net AHRI rating against the 725's 705 MBH and 613 MBH, at 690 lb with water versus 685 lb. Notably, its water content reads lower than the 725's — 16.5 gallons against 17.5 — so the larger input arrives without a heavier water volume.

The minimum fire rises from 72.5 to 85 MBH between the two, which is the sizing caution: the 850 only earns its place when the plant-demand calculation approaches its ceiling. Both are heating-only and documented in the TFTN500–850 I&O manual, and NTI positions the 285-to-850 MBH sizes for commercial applications.

CurrentSold in Canada
Input
72.5–725 MBH
Output (max)
—
AFUE
—

The NTI Trinity TFTN725 is the second-largest floor-mounted TFTN: 72.5 to 725 MBH input at 97.7% thermal efficiency, a 705 MBH heating capacity and a 613 MBH Net AHRI rating, stepping to 685 lb with water, 2 1/2" NPT water connections and 6" venting.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
85–850 MBH
Output (max)
—
AFUE
—

The NTI Trinity TFTN850 is the largest floor-mounted TFTN: 85 to 850 MBH input at 97.6% thermal efficiency, with an 825 MBH heating capacity and a 717 MBH Net AHRI rating, weighing 690 lb with water on 2 1/2" NPT water connections with 6" venting.

Natural gasPropaneHeating-only

Frequently asked questions

How does the TFTN850 differ from the TFTN725?

Input rises from 72.5–725 to 85–850 MBH, heating capacity from 705 to 825 MBH and the Net AHRI rating from 613 to 717 MBH; thermal efficiency eases from 97.7% to 97.6% and weight from 685 to 690 lb with water.

Do the two models share connections and venting?

Yes — both use 2 1/2" NPT water connections, a 1 1/4" NPT gas connection and 6" venting to 150 ft per side, per the NTI product page.

When is the TFTN850 worth the step?

When the plant-demand calculation approaches 850 MBH. Its 85 MBH minimum fire is the highest in the floor TFTN line, so a load the 725 can carry will cycle more on the 850.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.