NTI Trinity TFTN850
The NTI Trinity TFTN850 is the largest floor-mounted TFTN: 85 to 850 MBH input at 97.6% thermal efficiency, with an 825 MBH heating capacity and a 717 MBH Net AHRI rating, weighing 690 lb with water on 2 1/2" NPT water connections with 6" venting.
Key figures
- Max input
- 850 MBH
- Max CSA output
- —
- AFUE
- —
- Min input
- 85 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI Trinity TFTN850 in practice
The TFTN850 tops the TFTN family at 85 to 850 MBH input with 97.6% thermal efficiency, a heating capacity of 825 MBH and a Net AHRI rating of 717 MBH. It weighs 690 lb with water — 16.5 gallons of water content — and keeps the 2 1/2" male NPT water connections, 1 1/4" male NPT gas connection and 6" venting to 150 ft per side that the TFTN725 introduces.
At 690 lb the 850 is only 5 lb heavier than the 725 while adding 125 MBH of input ceiling, and its water content actually reads lower (16.5 gallons against 17.5). NTI positions the 285-to-850 MBH TFTN sizes for commercial applications, which makes the 850 the largest single-boiler statement of the TFTN platform; beyond it, NTI's commercial lineup steps to the Lx and FTG fire-tube series, and the model is documented in the TFTN500–850 I&O manual.
Best suited to
- Commercial hydronic plants whose load calculation approaches 850 MBH
- Large mechanical rooms already committed to 2 1/2" piping and 6" venting
- Plants wanting NTI's largest floor-mounted TFTN without leaving the touchscreen TFTN control family
Applicability and support
- Model number
- TFTN850
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 85 MBH | Per the NTI product page. |
| Input, maximum | 850 MBH | Per the NTI product page. |
| Output | ||
| Heating capacity | 825 MBH | Per the NTI product page. |
| Net AHRI rating | 717 MBH | Per the NTI product page. |
| Efficiency | ||
| Thermal efficiency | 97.6 % | Per the NTI product page; the floor TFTN models are rated by thermal efficiency rather than AFUE. |
| Domestic hot water | ||
| Domestic hot water | Heating-only; pair with an indirect tank or separate water heater | |
| Venting and air | ||
| Max. equivalent vent length, 6" | 150 ft | Inlet and exhaust runs, per the NTI product page. |
| Physical and connections | ||
| Weight | 690 lb | With water, per the NTI product page. |
| Water content | 16.5 gal | Per the NTI product page. |
| CH water connections | 2 1/2" NPT | Male NPT per the NTI product page. |
| Gas connection | 1 1/4" NPT | Male NPT per the NTI product page. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | NTI publishes LP conversion instructions for the TFTN500–850 size group. |
Manuals
- TFTN 085–399 I&O Manual, 99987137, V.2025-04-24 (HMI R30)99987137 · 2025-04-24
- TFTN 500–850 I&O Manual, 99987545, V.2025-04-2499987545 · 2025-04-24
Alerts documented for this model
- 101 1
- 102
- 103 1
- 104 1
- 105 1
- 106 1
- 109
- 110 1
- 112 1
- 113
- 114
- 115
- 117 1
- 118 1
- 150
- 1P1 1
- 1P2 1
- 1P3 1
- 1P4
- 203
- 209
- 2P2
- 303
- 304
- 306
- 309
- 3P9
- 411
- 412
- 413
- 441
- 460
- 501 1
- 502
- 504 1
- 5P1
- 5P2
- 5P6
- 5P3
- 5P5
- 602
- 603 1
- 605
- 608
- 612 1
- 730
- Unconfigured
- Conflict
- 101 1
- 102
- 103 1
- 104 1
- 105 1
- 106 1
- 109
- 110 1
- 112 1
- 113
- 114
- 115
- 117 1
- 118 1
- 150
- 1P1 1
- 1P2 1
- 1P3 1
- 1P4
- 203
- 209
- 2P2
- 303
- 304
- 306
- 309
- 3P9
- 411/412/413
- 441
- 460
- 501 1
- 502
- 504 1
- 5P1
- 5P2
- 5P6
- 5P3
- 5P5
- 602
- 603 1
- 605
- 608
- 612 1
- 730
- Unconfigured
- Conflict
Frequently asked questions
Is the TFTN850 the biggest TFTN?
Yes — the floor-mounted TFTN850 fires to 850 MBH input per the NTI product page, the top of the TFTN family. NTI's larger commercial fire-tube lines are the Lx and FTG series.
How does the TFTN850 compare with the TFTN725?
Input rises from 72.5–725 to 85–850 MBH, heating capacity from 705 to 825 MBH and the Net AHRI rating from 613 to 717 MBH; thermal efficiency eases from 97.7% to 97.6% and weight rises from 685 to 690 lb with water.
What venting does the TFTN850 use?
6" inlet and exhaust runs to 150 ft maximum each side, per the NTI product page — the same 6" class as the TFTN725.
Questions about the NTI Trinity TFTN850?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- NTI Trinity TFTN725 vs TFTN850Comparison
- NTI Trinity TFTN085Same series
- NTI Trinity TFTN110Same series
- NTI Trinity TFTN150Same series
- NTI Trinity TFTN199Same series
- NTI Trinity TFTN285Same series
- NTI Trinity TFTN340Same series
- NTI Trinity TFTN399Same series
- NTI Trinity TFTN500Same series
- NTI Trinity TFTN600Same series
- NTI Trinity TFTN725Same series
- Trinity TFTN series hub
- Buying guide
Sources and verification
- NTI — TFTN Series product page · accessed September 8, 2026
- TFTN 500–850 I&O Manual · 99987545 · accessed September 8, 2026
Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.