NTI Trinity TFTN725
The NTI Trinity TFTN725 is the second-largest floor-mounted TFTN: 72.5 to 725 MBH input at 97.7% thermal efficiency, a 705 MBH heating capacity and a 613 MBH Net AHRI rating, stepping to 685 lb with water, 2 1/2" NPT water connections and 6" venting.
Key figures
- Max input
- 725 MBH
- Max CSA output
- —
- AFUE
- —
- Min input
- 72.5 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
NTI Trinity TFTN725 in practice
The TFTN725 runs 72.5 to 725 MBH input at 97.7% thermal efficiency with a heating capacity of 705 MBH and a Net AHRI rating of 613 MBH. It moves to the large floor chassis: 685 lb with water, 17.5 gallons of water content, 2 1/2" male NPT water connections and a 1 1/4" male NPT gas connection, with 6" inlet and exhaust runs to 150 ft per side.
The 725 crosses two installation lines inside the TFTN floor family: the water connections step from 2" to 2 1/2" NPT and the venting from 4" to 6" pipe, so the mechanical-room plan changes at this size even though the efficiency story barely moves (97.7% against the 600's 97.8%). It is sized for commercial plants whose demand calculation sits between the 600 and the 850, with LP installations following NTI's TFTN500–850 conversion instructions.
Best suited to
- Commercial hydronic plants with load calculations between 600 and 725 MBH
- Buildings prepared for the 2 1/2" water connection and 6" venting class
- Plants wanting the floor TFTN platform's thermal-efficiency ratings near the top of the 500–850 range
Applicability and support
- Model number
- TFTN725
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by NTI Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 72.5 MBH | Per the NTI product page. |
| Input, maximum | 725 MBH | Per the NTI product page. |
| Output | ||
| Heating capacity | 705 MBH | Per the NTI product page. |
| Net AHRI rating | 613 MBH | Per the NTI product page. |
| Efficiency | ||
| Thermal efficiency | 97.7 % | Per the NTI product page; the floor TFTN models are rated by thermal efficiency rather than AFUE. |
| Domestic hot water | ||
| Domestic hot water | Heating-only; pair with an indirect tank or separate water heater | |
| Venting and air | ||
| Max. equivalent vent length, 6" | 150 ft | Inlet and exhaust runs, per the NTI product page. |
| Physical and connections | ||
| Weight | 685 lb | With water, per the NTI product page. |
| Water content | 17.5 gal | Per the NTI product page. |
| CH water connections | 2 1/2" NPT | Male NPT per the NTI product page. |
| Gas connection | 1 1/4" NPT | Male NPT per the NTI product page. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | NTI publishes LP conversion instructions for the TFTN500–850 size group. |
Manuals
- TFTN 085–399 I&O Manual, 99987137, V.2025-04-24 (HMI R30)99987137 · 2025-04-24
- TFTN 500–850 I&O Manual, 99987545, V.2025-04-2499987545 · 2025-04-24
Alerts documented for this model
- 101 1
- 102
- 103 1
- 104 1
- 105 1
- 106 1
- 109
- 110 1
- 112 1
- 113
- 114
- 115
- 117 1
- 118 1
- 150
- 1P1 1
- 1P2 1
- 1P3 1
- 1P4
- 203
- 209
- 2P2
- 303
- 304
- 306
- 309
- 3P9
- 411
- 412
- 413
- 441
- 460
- 501 1
- 502
- 504 1
- 5P1
- 5P2
- 5P6
- 5P3
- 5P5
- 602
- 603 1
- 605
- 608
- 612 1
- 730
- Unconfigured
- Conflict
- 101 1
- 102
- 103 1
- 104 1
- 105 1
- 106 1
- 109
- 110 1
- 112 1
- 113
- 114
- 115
- 117 1
- 118 1
- 150
- 1P1 1
- 1P2 1
- 1P3 1
- 1P4
- 203
- 209
- 2P2
- 303
- 304
- 306
- 309
- 3P9
- 411/412/413
- 441
- 460
- 501 1
- 502
- 504 1
- 5P1
- 5P2
- 5P6
- 5P3
- 5P5
- 602
- 603 1
- 605
- 608
- 612 1
- 730
- Unconfigured
- Conflict
Frequently asked questions
What changes between the TFTN600 and the TFTN725?
Input rises from 60–600 to 72.5–725 MBH, heating capacity from 585 to 705 MBH and the Net AHRI rating from 509 to 613 MBH. Weight rises from 575 to 685 lb with water, connections step to 2 1/2" water and 1 1/4" gas, and venting moves from 4" to 6" pipe.
What is the TFTN725's efficiency?
97.7% thermal efficiency per the NTI product page, against 97.8% on the TFTN600 and 97.6% on the TFTN850.
Does the TFTN725 fit the TFTN500's venting plan?
No — NTI lists 6" inlet and exhaust runs for the TFTN725, to 150 ft maximum each side, while the TFTN500 and TFTN600 use 4" pipe.
Questions about the NTI Trinity TFTN725?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- NTI Trinity TFTN600 vs TFTN725Comparison
- NTI Trinity TFTN725 vs TFTN850Comparison
- NTI Trinity TFTN085Same series
- NTI Trinity TFTN110Same series
- NTI Trinity TFTN150Same series
- NTI Trinity TFTN199Same series
- NTI Trinity TFTN285Same series
- NTI Trinity TFTN340Same series
- NTI Trinity TFTN399Same series
- NTI Trinity TFTN500Same series
- NTI Trinity TFTN600Same series
- NTI Trinity TFTN850Same series
- Trinity TFTN series hub
- Buying guide
Sources and verification
- NTI — TFTN Series product page · accessed September 8, 2026
- TFTN 500–850 I&O Manual · 99987545 · accessed September 8, 2026
Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.