NTI Trinity TRX120 vs TRX150

Verdict in brief

The TRX120 and TRX150 are both 95% AFUE heating-only TRX boilers, and the 150 steps the input ceiling from 120 to 150 MBH. The price of that headroom is physical: the 150 weighs 115 lb against 88.6 lb and moves from 1" sweat to 1 1/4" NPT CH connections, while its minimum fire rises from 13.2 to 15 MBH.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity TRX120 and NTI Trinity TRX150
SpecificationNTI Trinity TRX120NTI Trinity TRX150
Input, minimum13.2 MBH15 MBH
Input, maximum120 MBH150 MBH
Efficiency (AFUE)95 %95 %
Turndown ratioup to 11:1up to 11:1
Weight88.6 lb115 lb
Max. equivalent vent length, 2"100 ft100 ft
Max. equivalent vent length, 3"150 ft150 ft
CH water connections1" male sweat with adapter1 1/4" NPT
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both models share the TRX platform at 95% AFUE with the same 2" (100 ft) and 3" (150 ft) venting terms. The differences start with the cabinet: the TRX120 weighs 88.6 lb with 1" male sweat CH connections, while the TRX150 weighs 115 lb and steps up to 1 1/4" NPT CH connections.

Firing ranges are 13.2 to 120 MBH for the 120 and 15 to 150 MBH for the 150. The minimum fire rises only 1.8 MBH, so the 150 does not cost much low-load behaviour for its extra 30 MBH of ceiling — the real costs are the extra 26.4 lb of handling weight and the larger near-boiler piping.

Both are heating-only, so an indirect tank or separate water heater serves domestic hot water on either. The 150 is the natural step when the heat-loss calculation plus recovery demand exceeds 120 MBH; houses that fit inside the 120 keep the lighter unit and the simpler 1" sweat connections.

CurrentSold in Canada
Input
13.2–120 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity TRX120 is the 95% AFUE heating-only TRX between the 85 and the 150: it fires 13.2 to 120 MBH at just 88.6 lb, keeping the lightest chassis class in the series with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
15–150 MBH
Output (max)
—
AFUE
95 %

The NTI Trinity TRX150 is the 95% AFUE heating-only TRX for larger homes: 15 to 150 MBH input, stepping up to 1 1/4" NPT CH connections and 115 lb, with 2" venting to 100 ft or 3" to 150 ft per side.

Natural gasPropaneHeating-only

Frequently asked questions

What changes between the TRX120 and the TRX150?

Input rises from 120 to 150 MBH, weight from 88.6 to 115 lb, and CH connections from 1" male sweat to 1 1/4" NPT. Both are heating-only at 95% AFUE.

Does the TRX150 still allow 2" venting?

Yes — 2" runs to 100 ft per side remain available on the TRX150, with 3" allowed to 150 ft.

When should I stay on the TRX120?

When the calculated load fits within 120 MBH. The 120 keeps the lighter 88.6 lb unit and 1" connections, and its 13.2 MBH minimum fire is the lowest of the two.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate