Crown Phantom II PHTM2150H vs PHTM2180H

Verdict in brief

The PHTM2150H and PHTM2180H are the two large-cabinet Phantom II heat-only sizes: identical 95.0% AFUE, 10:1 modulation, 20.4 × 17.8 × 29.8 inch cabinet, 132 lb shipping weight and 1.0 gal water content. The 2180H adds 30 MBH of input ceiling (180 vs 150 MBH), lifting DOE capacity from 141 to 169 MBH and net AHRI from 123 to 147 MBH, with the same 20 MBH minimum fire.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Crown Phantom II PHTM2150H and Crown Phantom II PHTM2180H
SpecificationCrown Phantom II PHTM2150HCrown Phantom II PHTM2180H
Input, minimum20 MBH20 MBH
Input, maximum150 MBH180 MBH
DOE heating capacity141 MBH169 MBH
Net AHRI water rating123 MBH147 MBH
Efficiency (AFUE)95 %95 %
Turndown ratio10:110:1
Boiler water content1 gal1 gal
Shipping weight132 lb132 lb
Dimensions (D × W × H)20.4" × 17.8" × 29.8"20.4" × 17.8" × 29.8"
Max. equivalent vent length, 2"70 ft70 ft
Max. equivalent vent length, 3"135 ft135 ft
Heating water connections1" sweat1" sweat
Gas connection1/2" MPT1/2" MPT
Maximum allowable working pressure (MAWP)50 psig50 psig
Electrical120 VAC, 60 Hz, 1-phase, 1.8 A120 VAC, 60 Hz, 1-phase, 1.8 A
FuelNatural gas or LPNatural gas or LP
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater

What actually separates them

Both models share the large 20.4 × 17.8 × 29.8 inch cabinet at 132 lb shipping with 1.0 gal of water content, the same 20 MBH minimum fire, 1" sweat supply/return, 1/2" MPT gas, 50 psig MAWP and 2"/3" venting to 70/135 ft — all at 95.0% AFUE on the gas-adaptive 'PHTM II' control.

The 2180H exists purely for top-end capacity: its 180 MBH maximum input prints 169 MBH DOE heating capacity and a 147 MBH net AHRI water rating, against the 2150H's 150 MBH maximum, 141 MBH DOE and 123 MBH net AHRI.

Because both fire down to the same 20 MBH minimum, low-load behaviour is identical — the choice is entirely whether the heat-loss calculation plus recovery demand approaches 141 MBH of DOE capacity (2150H) or 169 MBH (2180H). On LP above 8,000 ft both are limited to 50 ft equivalent vent length.

CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
AFUE
95 %

The Crown Phantom II PHTM2150H fires 20 to 150 MBH at 95.0% AFUE with 141 MBH DOE heating capacity and a 123 MBH net AHRI rating, stepping to the deeper 20.4-inch cabinet at 132 lb shipping.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–180 MBH
Output (max)
AFUE
95 %

The Crown Phantom II PHTM2180H is the largest Phantom II heat-only boiler: 20 to 180 MBH input at 95.0% AFUE with 169 MBH DOE heating capacity and a 147 MBH net AHRI rating, in the same 132 lb large cabinet as the 2150H.

Natural gasPropaneHeating-only

Frequently asked questions

What separates the PHTM2150H and PHTM2180H?

Only top-end capacity: 150 vs 180 MBH maximum input, 141 vs 169 MBH DOE heating capacity and 123 vs 147 MBH net AHRI. Cabinet, weight, minimum fire and connections are identical.

Do both sizes share vent limits?

Yes — 2" to 70 ft or 3" with increaser to 135 ft, with both limited to 50 ft equivalent on LP above 8,000 ft.

Which should I choose?

The one a heat-loss calculation supports. Since both start at 20 MBH minimum fire, extra ceiling you never use buys nothing except more boiler than the load needs.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.