Verdict in brief

Stepping from the Solo 110 to the Solo 155 raises the firing ceiling from 110 to 153 MBH and the DOE capacity from 102 to 142 MBH, at the cost of a higher minimum fire (27.8 against 20 MBH), a heavier cabinet (118 lb against 103) and larger connections (1 1/4" supply/return and 3/4" gas against 1" and 1/2"). Both stay on 3" venting in the same 19 3/4-inch-wide footprint.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Triangle Tube Prestige Solo 110 and Triangle Tube Prestige Solo 155
SpecificationTriangle Tube Prestige Solo 110Triangle Tube Prestige Solo 155
Heating input, minimum20 MBH27.8 MBH
Heating input, maximum110 MBH153 MBH
Efficiency (AFUE)95 %95 %
DOE heating capacity102 MBH142 MBH
Net AHRI rating89 MBH123 MBH
Turndown ratio5.5:15.5:1
Water volume2.1 gal4 gal
Weight103 lb118 lb
Vent/air diameter3"3"
Supply/return connections1"1 1/4"
Gas connection1/2"3/4"

What actually separates them

The Solo 110 and Solo 155 share the 19 3/4" cabinet width and 3" vent/air diameter, but the 155 is a bigger internal package: 118 lb against 103 lb and 4 gallons of water against 2.1, with supply/return connections stepping from 1" to 1 1/4" and the gas line from 1/2" to 3/4".

The capacity jump is 153 MBH maximum input against 110 MBH — note the 155's true ceiling — and DOE capacity rises from 102 to 142 MBH with net AHRI from 89 to 123 MBH. The minimum fire rises from 20 to 27.8 MBH, so the larger model gives up a little low-fire tracking to gain 43 MBH of ceiling.

Both sizes are documented for the installed base after the November 3, 2025 cessation. PA110/PT110 and PA155 serial rows appear in the Health Canada recall table, so owners of either generation should verify prefixes against the official list.

DiscontinuedHistorically in Canada
Input
20–110 MBH
Output (max)
—
AFUE
95 %

The Prestige Solo 110 fires 20 to 110 MBH at 95% AFUE in the same 103 lb, 19 3/4-inch-wide cabinet as the Solo 80 — historically the best-known Prestige size, spanning the MCBA (gen-1) through CTRLMax generations. Discontinued with the November 3, 2025 cessation.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
27.8–153 MBH
Output (max)
—
AFUE
95 %

The Prestige Solo 155 modulates from 27.8 to 153 MBH at 95% AFUE — the model number reads 155 but the maximum input is 153 MBH — adding 15 lb and stepping the connections up to 1 1/4" supply/return versus the smaller Solo sizes. Discontinued with the November 3, 2025 cessation.

Natural gasPropaneHeating-only

Frequently asked questions

What is the biggest difference between the Solo 110 and Solo 155?

Capacity and connections: the 155 fires to 153 MBH against 110 MBH, with 142 MBH DOE capacity against 102 MBH, and it steps up to 1 1/4" supply/return and 3/4" gas connections.

Does the Solo 155 weigh much more than the Solo 110?

118 lb against 103 lb, in the same 19 3/4"-wide cabinet. The 155 also holds 4 gallons of water against 2.1 gallons.

Which size is right for my house?

The one that fits the room-by-room heat-loss calculation. If the design load stays under 110 MBH the Solo 110's lower 20 MBH minimum fire and lighter cabinet are advantages; above that, the 155's ceiling is the point.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate