Skip to content
Boilers.caby ROMA Heating & Cooling

Triangle Tube · Prestige Solo

Triangle Tube Prestige Solo 155

The Prestige Solo 155 modulates from 27.8 to 153 MBH at 95% AFUE — the model number reads 155 but the maximum input is 153 MBH — adding 15 lb and stepping the connections up to 1 1/4" supply/return versus the smaller Solo sizes. Discontinued with the November 3, 2025 cessation.

DiscontinuedHistorically in Canada

Key figures

Max input
153 MBH
Max CSA output
AFUE
95 %
Min input
27.8 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Triangle Tube Prestige Solo 155 in practice

The Solo 155 was added to the Prestige line in the generation update that also brought the 299 and replaced the 60 with the 80, per Triangle Tube's 2019 marketing. Its published range is 27.8 to 153 MBH at 95% AFUE with 5.5:1 turndown, 142 MBH DOE capacity and a 123 MBH net AHRI rating — note that the '155' name overstates the true 153 MBH ceiling, which is exactly why sizing follows the spec table rather than the model number.

Physically the 155 steps up from the smaller sizes: 118 lb against 103 lb, 4 gallons of water volume against 2.1, and 1 1/4" supply/return connections with a 3/4" gas connection, all in the same 19 3/4"-wide cabinet with 3" vent/air piping. Triangle Tube ceased operations November 3, 2025; this model is documented for the installed base.

Best suited to

  • Homes whose heat-loss calculation lands between the 110 and the 175 sizes
  • Radiator systems whose flow needs the larger 1 1/4" supply/return connections
  • Replacing mid-size older boilers where the 19 3/4" cabinet width fits the wall

Applicability and support

Model number
Unknown
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Triangle Tube. Units are shown with every value; notes flag conflicting sources or missing figures.

Triangle Tube Prestige Solo 155 specifications
SpecificationValueNote
Input
Heating input, minimum27.8 MBHThe product page and manual print the Solo 155 maximum at 153 MBH, not 155.
Heating input, maximum153 MBHThe product page and manual print the Solo 155 maximum at 153 MBH, not 155.
Output
DOE heating capacity142 MBHPer the product-page spec table.
Net AHRI rating123 MBHPer the product-page spec table.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the product-page spec table.
Venting and air
Vent/air diameter3"Per the product-page spec table.
Physical and connections
Water volume4 gal
Weight118 lb
Width19.75 in19 3/4" x 36 9/16" x 17 5/16" as printed.
Height36.563 in
Depth17.313 in
Supply/return connections1 1/4"
Gas connection3/4"
Operating limits and other
FuelNatural gas or propane
Turndown ratio5.5:1The page prints 5:5:1; 153 MBH divided by the 27.8 MBH minimum equals 5.5:1.
Maximum CH flow temperature185 °FPer the I&M manual.

Frequently asked questions

Why is the Solo 155 called 155 when it fires to 153 MBH?

The Prestige marketing names follow rounded sizes, and the spec table is the authority: the Solo 155 fires 27.8 to 153 MBH while the Solo 175 fires 30.9 to 170 MBH. Only the Instinct series model numbers match their full firing rates.

What connections does the Solo 155 use?

The product page lists 1 1/4" supply/return connections and a 3/4" gas connection, with 3" vent/air diameter — a step up from the 1" and 1/2" fittings of the Solo 80 and 110.

Questions about the Triangle Tube Prestige Solo 155?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate