Triangle Tube Prestige Solo 250 vs Solo 299

Verdict in brief

Moving from the Solo 250 to the Solo 299 changes more than capacity: the 299 steps into the large 24 7/8-inch cabinet at 210 lb, requires 4" vent/air piping and 1 1/2" supply/return connections with a 1" gas line, and its minimum fire rises from 43.6 to 72.5 MBH. In exchange it fires to 299 MBH against 240 MBH with 278 MBH DOE capacity against 222 MBH.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Triangle Tube Prestige Solo 250 and Triangle Tube Prestige Solo 299
SpecificationTriangle Tube Prestige Solo 250Triangle Tube Prestige Solo 299
Heating input, minimum43.6 MBH72.5 MBH
Heating input, maximum240 MBH299 MBH
Efficiency (AFUE)95 %95 %
DOE heating capacity222 MBH278 MBH
Net AHRI rating193 MBH242 MBH
Water volume4.5 gal7.4 gal
Weight140 lb210 lb
Vent/air diameter3"4"
Supply/return connections1 1/4"1 1/2"
Gas connection3/4"1"

What actually separates them

The 250-to-299 step is the physical break in the Prestige line: the 250 keeps the compact 19 3/4" x 36 9/16" x 17 5/16" cabinet with 3" venting and 1 1/4" supply/return connections, while the 299 moves to the large 24 7/8" x 39 3/8" x 23 5/8" cabinet at 210 lb with 4" venting, 1 1/2" supply/return and a 1" gas connection — a different mechanical-room plan entirely.

Capacity follows the chassis: the 299 fires 72.5 to 299 MBH against the 250's 43.6 to 240 MBH, with 278 MBH DOE capacity and a 242 MBH net AHRI rating against 222 and 193 MBH. The 299's 72.5 MBH minimum fire — the same as the 399's — means it only suits loads that genuinely approach its range; between the two, the 250's lower minimum and 3" venting keep it the flexible choice.

Turndown rows for both sizes on the product page contradict their input ranges and are flagged as unreliable in the research bundle, so comparisons use the printed input ranges. Both sizes are documented for the installed base after the November 3, 2025 cessation.

DiscontinuedHistorically in Canada
Input
43.6–240 MBH
Output (max)
—
AFUE
95 %

The Prestige Solo 250 fires 43.6 to 240 MBH at 95% AFUE in the last of the 19 3/4-inch cabinets, rated 222 MBH DOE capacity — and it is one of the two sizes the Prestige Cascade kits are built around. Discontinued with the November 3, 2025 cessation.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
72.5–299 MBH
Output (max)
—
AFUE
95 %

The Prestige Solo 299 fires 72.5 to 299 MBH at 95% AFUE — the size added in the generation update alongside the 155 — stepping the line up to a 24 7/8-inch cabinet, 4" vent/air piping and 1 1/2" connections. Discontinued with the November 3, 2025 cessation.

Natural gasPropaneHeating-only

Frequently asked questions

Does the Solo 299 fit where a Solo 250 fit?

No. The 299 is the start of the large chassis: 24 7/8" x 39 3/8" x 23 5/8" at 210 lb against 19 3/4" x 36 9/16" x 17 5/16" at 140 lb, with 4" venting replacing 3" and 1 1/2" supply/return replacing 1 1/4".

What do the Solo 250 and Solo 299 minimum fires mean in practice?

The 299 cannot fire below 72.5 MBH while the 250 goes down to 43.6 MBH. In any building whose load is well under the 299's ceiling, the 250 will track shoulder-season demand far better.

Is the Solo 299 still sold?

No. Triangle Tube ceased operations November 3, 2025, and no Prestige size is sold new. This comparison serves owners sizing replacements and service work on the installed base.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate