The Prestige Solo 250 fires 43.6 to 240 MBH at 95% AFUE in the last of the 19 3/4-inch cabinets, rated 222 MBH DOE capacity — and it is one of the two sizes the Prestige Cascade kits are built around. Discontinued with the November 3, 2025 cessation.

DiscontinuedHistorically in Canada

Key figures

Max input
240 MBH
Max CSA output
—
AFUE
95 %
Min input
43.6 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Triangle Tube Prestige Solo 250 in practice

The Solo 250 is the top of the compact 19 3/4"-wide group: 43.6 to 240 MBH of input — the '250' name overstates the 240 MBH ceiling — with 222 MBH DOE capacity, a 193 MBH net AHRI rating and 3" vent/air piping on a 140 lb cabinet holding 4.5 gallons. Its minimum fire of 43.6 MBH is noticeably higher than the smaller sizes, so it belongs to buildings whose calculated load actually approaches the top of its range.

Beyond single-boiler service, the Prestige Cascade C500 kit combines two Solo 250 boilers for a total input of 65 to 490 MBH, per the cascade product page. For owners of recalled-generation units, PA250 serials (December 2015-April 2019) appear in the Health Canada table alongside the earlier PT250 range. Triangle Tube ceased operations November 3, 2025; this model is documented for the installed base.

Best suited to

  • Large homes and small buildings whose heat-loss calculation reaches 200+ MBH
  • Two-boiler Prestige Cascade C500 arrangements (2 x Solo 250)
  • Installations needing the 3" vent size and the last of the compact cabinets

Applicability and support

Model number
Unknown
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Triangle Tube. Units are shown with every value; notes flag conflicting sources or missing figures.

Triangle Tube Prestige Solo 250 specifications
SpecificationValueNote
Input
Heating input, minimum43.6 MBHThe product page and manual print the Solo 250 maximum at 240 MBH, not 250.
Heating input, maximum240 MBHThe product page and manual print the Solo 250 maximum at 240 MBH, not 250.
Output
DOE heating capacity222 MBHPer the product-page spec table.
Net AHRI rating193 MBHPer the product-page spec table.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the product-page spec table.
Venting and air
Vent/air diameter3"Per the product-page spec table.
Physical and connections
Water volume4.5 gal
Weight140 lb
Width19.75 in19 3/4" x 36 9/16" x 17 5/16" as printed.
Height36.563 in
Depth17.313 in
Supply/return connections1 1/4"
Gas connection3/4"
Operating limits and other
FuelNatural gas or propane
Turndown ratio4.1:1The page prints 4:1:1, but 240 MBH divided by the 43.6 MBH minimum equals 5.5:1 — the research bundle flags the Solo 250/299 turndown rows as transposed and unreliable.
Maximum CH flow temperature185 °FPer the I&M manual.

Frequently asked questions

Why does the page show a 4:1 turndown for the Solo 250?

The product page's turndown row for the Solo 250 reads 4:1:1, which contradicts the same table's own 43.6 to 240 MBH input range (5.5:1). The research bundle flags the Solo 250 and 299 turndown rows as transposed or typo'd, so the input range is the reliable figure.

What is the Solo 250 used for in a Prestige Cascade?

The Prestige Cascade C500 kit combines two Solo 250 boilers for total inputs of 65 to 490 MBH, with cascade outputs of up to 6 boilers supported by the CTRLMax cascade function.

Questions about the Triangle Tube Prestige Solo 250?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate