Triangle Tube Prestige Solo 299
The Prestige Solo 299 fires 72.5 to 299 MBH at 95% AFUE — the size added in the generation update alongside the 155 — stepping the line up to a 24 7/8-inch cabinet, 4" vent/air piping and 1 1/2" connections. Discontinued with the November 3, 2025 cessation.
Key figures
- Max input
- 299 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 72.5 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Triangle Tube Prestige Solo 299 in practice
The Solo 299 crosses into the large-cabinet group: 24 7/8" wide by 39 3/8" tall and 23 5/8" deep at 210 lb with 7.4 gallons of water volume, 4" vent/air diameter, 1 1/2" supply/return connections and a 1" gas connection. Its rating set is 72.5 to 299 MBH at 95% AFUE with 278 MBH DOE capacity and a 242 MBH net AHRI rating.
The 299's 72.5 MBH minimum fire is the same as the 399's and much higher than the compact sizes, so the 299 is a capacity-driven choice for larger loads and cascade plants rather than a modulation play. PA299 serials (December 2015-April 2019) appear in the Health Canada recall table. Triangle Tube ceased operations November 3, 2025; this model is documented for the installed base.
Best suited to
- Buildings whose heat-loss calculation approaches the 299 MBH ceiling
- Radiator and in-floor systems needing the 1 1/2" supply/return fittings
- Cascade arrangements that pair large Prestige sizes on a common plant
Applicability and support
- Model number
- Unknown
- Canadian availability
- historical
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Triangle Tube. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 72.5 MBH | |
| Heating input, maximum | 299 MBH | |
| Output | ||
| DOE heating capacity | 278 MBH | Per the product-page spec table. |
| Net AHRI rating | 242 MBH | Per the product-page spec table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95% AFUE per the product-page spec table. |
| Venting and air | ||
| Vent/air diameter | 4" | Per the product-page spec table. |
| Physical and connections | ||
| Water volume | 7.4 gal | |
| Weight | 210 lb | |
| Width | 24.875 in | 24 7/8" x 39 3/8" x 23 5/8" as printed. |
| Height | 39.375 in | |
| Depth | 23.625 in | |
| Supply/return connections | 1 1/2" | |
| Gas connection | 1" | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | |
| Turndown ratio | 5.5:1 | The page prints 5:5:1, but 299 MBH divided by the 72.5 MBH minimum equals 4.1:1 — the research bundle flags the Solo 250/299 turndown rows as transposed and unreliable. |
| Maximum CH flow temperature | 185 °F | Per the I&M manual. |
Manuals
- Prestige Solo 80-399 Installation & Maintenance ManualA1010763-664A0700 Rev. E · 2019-06
Alerts documented for this model
- E1
- E2
- E3
- E5
- E7
- E8
- E9
- E12
- E13
- E15
- E16
- E17
- E18
- E19
- E21
- E25
- E30
- E31
- E32
- E33
- E34
- E37
- E43
- E44
- E45
- E46
- E47
- E76
- E77
- E78
- E79
- E80
- E81
- E82
- E83
- E84
- E87
- E89
- E90
- E91
- E92
- E93
- E94
- E95
- E96
- E97
- E98
- E99
- E00
- E02
- E03
- E04
- E05
- E06
- E07
- E08
- E09
- E11
- E12
- E13
- E14
- E15
- E16
- E17
- E18
- E19
- E25
- E28
- E29
- E31
- E32
- E35
- E36
- E37
- E40
- E44
- E52
- E60
- E61
- E65
- E113
- E115
- E122
- E123
- E124
- E1
- E2
- E3
- E5
- E8
- E9
- E13
- E15
- E16
- E17
- E18
- E21
- E30
- E31
- E43
- E44
- E80
- E87
- E7
- E12
- E25
- E32
- E33
- E34
- E37
- E45
- E46
- E76
- E81
- E89
- E90
- E91
- E92
- E93
- E94
- E95
- E96
- E97
- E98
- E99
- E1
- E2
- E3
- E5
- E8
- E9
- E13
- E15
- E16
- E17
- E18
- E21
- E30
- E31
- E43
- E44
- E47
- E80
- E87
- E7
- E12
- E25
- E32
- E33
- E34
- E37
- E45
- E46
- E76
- E81
- E89
- E90
- E91
- E92
- E93
- E94
- E95
- E96
- E97
- E98
- E99
Frequently asked questions
Does the Solo 299 fit where a Solo 250 fit?
No. The 299 moves to the large 24 7/8" x 39 3/8" x 23 5/8" cabinet (210 lb), requires 4" vent/air piping and 1 1/2" supply/return connections, and steps the gas line to 1" — a different mechanical-room plan from the 19 3/4"-wide sizes.
Why is the Solo 299's turndown row unreliable?
The page prints 5:5:1 for the 299 even though its own input range of 72.5 to 299 MBH computes to about 4.1:1. The research bundle flags the Solo 250 and 299 turndown rows as transposed, so size decisions should use the printed input ranges.
Questions about the Triangle Tube Prestige Solo 299?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Triangle Tube Prestige Solo 250 vs Solo 299Comparison
- Triangle Tube Prestige Solo 299 vs Solo 399Comparison
- Triangle Tube Prestige Solo 80Same series
- Triangle Tube Prestige Solo 110Same series
- Triangle Tube Prestige Solo 155Same series
- Triangle Tube Prestige Solo 175Same series
- Triangle Tube Prestige Solo 250Same series
- Triangle Tube Prestige Solo 399Same series
- Prestige Solo series hub
- Buying guide
Sources and verification
- Prestige Solo 80-399 Installation & Maintenance Manual, A1010763 Rev. E (2019-06) · accessed September 7, 2026
- Health Canada — joint recall RA-77029 (Prestige Solo PT/PA serial tables) · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.