Slant/Fin Victory VSPH-120 vs VSPH-150

Verdict in brief

The VSPH-120 and VSPH-150 are the middle and second-largest Victory VSPH sizes — discontinued NON-condensing cast-iron direct-vent boilers on identical 3" AL29-4C stainless venting at 50 psi MAWP. The 150 fires 150,000 Btuh across 6 sections against the 120's 120,000 Btuh across 5, at the cost of shorter flue runs: 35/30/25 ft versus 40/35/30 ft by elevation on Saf-T systems.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Slant/Fin VSPH-120 and Slant/Fin VSPH-150
SpecificationSlant/Fin VSPH-120Slant/Fin VSPH-150
Input120 MBH150 MBH
Cast-iron sections56
VentingDirect vent, sealed combustion — mechanically induced draft, positive-pressure flue: 3" diameter UL-listed AL29-4C stainless steel only (Heat-Fab Saf-T Vent / Saf-T EZ Seal, ProTech FasNSeal, Flex-L StaR-34 or Z-Flex Z-Vent); NO PVC/plastic or galvanized flue; no vent damper; common venting not allowedDirect vent, sealed combustion — mechanically induced draft, positive-pressure flue: 3" diameter UL-listed AL29-4C stainless steel only (Heat-Fab Saf-T Vent / Saf-T EZ Seal, ProTech FasNSeal, Flex-L StaR-34 or Z-Flex Z-Vent); NO PVC/plastic or galvanized flue; no vent damper; common venting not allowed
Max. flue equivalent length (Heat-Fab Saf-T / EZ Seal)40 ft (0–5,000 ft) / 35 ft (5,000–7,500 ft) / 30 ft (7,500–10,000 ft)35 ft (0–5,000 ft) / 30 ft (5,000–7,500 ft) / 25 ft (7,500–10,000 ft)
FuelNatural gas or propaneNatural gas or propane
Maximum allowable working pressure (MAWP)50 psi50 psi
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect water heater (indirect connections supported by the control)Heating-only boiler — domestic hot water comes from a separate indirect water heater (indirect connections supported by the control)

What actually separates them

Both are cast-iron, NON-condensing, floor-standing direct-vent boilers of the discontinued VSPH series: mechanically induced draft, positive-pressure flue in 3" UL-listed AL29-4C stainless steel only, HydroStat 3000 control, 50 psi ASME MAWP with a 30 psi relief valve.

The VSPH-150 raises fixed input from 120,000 to 150,000 Btuh and the section count from 5 to 6; jacket width (A) grows from 17-1/8" to 20-1/8" and dimension B from 23-3/8" to 26-3/8" per Figure 1.

The larger size trades flue length: on Heat-Fab Saf-T / EZ Seal systems the 150 is allowed 35 ft below 5,000 ft, 30 ft at 5,000–7,500 ft and 25 ft at 7,500–10,000 ft, versus 40/35/30 ft for the 120. Air intake drops to 35 ft above 7,500 ft on the 150, where the 120 keeps 40 ft.

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Slant/Fin Victory VSPH-120 fires 120,000 Btuh fixed input across 5 cast-iron sections: a discontinued, NON-condensing, floor-standing direct-vent boiler whose 3" stainless flue steps down from 40 to 30 ft with elevation.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Slant/Fin Victory VSPH-150 fires 150,000 Btuh fixed input across 6 cast-iron sections: a discontinued, NON-condensing, floor-standing direct-vent boiler whose 3" stainless flue maxes at 35 ft below 5,000 ft.

Natural gasPropaneHeating-only

Frequently asked questions

How does the VSPH-150 differ from the VSPH-120?

Input rises from 120,000 to 150,000 Btuh, sections from 5 to 6, jacket width (A) from 17-1/8" to 20-1/8" — and flue allowance falls from 40 to 35 ft below 5,000 ft.

Do both need stainless venting?

Yes — every VSPH vents in 3" AL29-4C stainless steel; plastic or galvanized flue is not allowed.

Which VSPH allows a longer vent run?

The smaller VSPH-120: 40/35/30 ft versus the VSPH-150's 35/30/25 ft by elevation band on Saf-T / EZ Seal systems.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate