Slant/Fin VSPH-150

The Slant/Fin Victory VSPH-150 fires 150,000 Btuh fixed input across 6 cast-iron sections: a discontinued, NON-condensing, floor-standing direct-vent boiler whose 3" stainless flue maxes at 35 ft below 5,000 ft.

DiscontinuedCanadian status unknown

Key figures

Max input
150 MBH
Max CSA output
AFUE
Min input
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Slant/Fin VSPH-150 in practice

The VSPH-150 is the second-largest Victory VSPH: a cast-iron, gas-fired, floor-standing boiler that is NOT condensing, firing a fixed 150,000 Btuh across 6 cast-iron sections. Mechanically induced draft with a sealed-combustion direct-vent, positive-pressure flue, it must vent in 3" UL-listed AL29-4C stainless steel — no PVC/plastic or galvanized flue, no vent damper, no common venting. Jacket width (A) is 20-1/8" with dimension B 26-3/8" per Figure 1 (+1-1/2" height and 28-1/2" depth with the combustible floor kit).

The I&O venting table steps the flue allowance down with size and elevation: 35 ft at 0–5,000 ft, 30 ft at 5,000–7,500 ft and 25 ft at 7,500–10,000 ft on Heat-Fab Saf-T / EZ Seal systems (air intake 40 ft below 7,500 ft, 35 ft above); Z-Flex Z-Vent allows 30/25/20 ft and ProTech FasNSeal 25/20/15 ft. The HydroStat 3000 control runs natural gas or field-converted LP at 50 psi ASME MAWP with a 30 psi relief valve.

The VSPH is discontinued and listed under 'Vintage', and the library page hosts the 2018 heat-exchanger RECALL notices — owners of a VSPH-150 should confirm their unit's status against those notices. canadianStatus stays 'unknown'; a licensed contractor handles gas, venting and combustion work.

Best suited to

  • Larger homes whose direct-vent load is a fixed 150,000 Btuh input in an existing VSPH
  • Owners checking VSPH-150 ratings, altitude vent limits and recall status
  • Contractors documenting the upper range of the discontinued cast-iron direct-vent line

Applicability and support

Model number
VSPH-150
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Slant/Fin. Units are shown with every value; notes flag conflicting sources or missing figures.

Slant/Fin VSPH-150 specifications
SpecificationValueNote
Input
Input150 MBH150,000 Btuh fixed gas input per the ratings and dimensions data in the VSPH I&O manual (Pub. VSPH-41 Rev. C).
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect water heater (indirect connections supported by the control)
Venting and air
VentingDirect vent, sealed combustion — mechanically induced draft, positive-pressure flue: 3" diameter UL-listed AL29-4C stainless steel only (Heat-Fab Saf-T Vent / Saf-T EZ Seal, ProTech FasNSeal, Flex-L StaR-34 or Z-Flex Z-Vent); NO PVC/plastic or galvanized flue; no vent damper; common venting not allowedMinimum flue length 2 ft; max equivalent lengths by model and vent-system manufacturer. Combustion air intake: 3" PVC Schedule 40 or galvanized steel. Flue gas may partially condense in the blower discharge — the boiler has a factory condensate drain and water trap.
Max. flue equivalent length (Heat-Fab Saf-T / EZ Seal)35 ft (0–5,000 ft) / 30 ft (5,000–7,500 ft) / 25 ft (7,500–10,000 ft)By elevation band 0–5,000 / 5,000–7,500 / 7,500–10,000 ft per the I&O manual's venting table; other listed systems allow shorter runs (e.g. ProTech FasNSeal).
Physical and connections
Cast-iron sections6Cast-iron sections assembled with metal push nipples (ASME 'H' stamp), per the VSPH I&O manual Figure 1.
Operating limits and other
FuelNatural gas or propaneField-convertible NG-to-LP gas valve; orifice chart covers elevations to 10,000 ft (4% derate per 1,000 ft).
Maximum allowable working pressure (MAWP)50 psi50 psi ASME working pressure with a factory-supplied 30 psi safety relief valve, per the VSPH master specification.

Frequently asked questions

What flue length does the VSPH-150 allow?

35 ft maximum equivalent at 0–5,000 ft, 30 ft at 5,000–7,500 ft and 25 ft at 7,500–10,000 ft on Heat-Fab Saf-T / EZ Seal systems.

How does the VSPH-150 differ from the VSPH-120?

Input rises from 120,000 to 150,000 Btuh, sections from 5 to 6, jacket width (A) from 17-1/8" to 20-1/8" and dimension B from 23-3/8" to 26-3/8" — while maximum flue length falls from 40 to 35 ft at low elevation.

Is the VSPH-150 available for new installation?

No — Slant/Fin lists the VSPH under 'Vintage' and the line is discontinued; the 2018 recall notices apply to the series.

Questions about the Slant/Fin VSPH-150?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate