Slant/Fin Victory VSPH-60 vs VSPH-90

Verdict in brief

The VSPH-60 and VSPH-90 are the two smallest discontinued Victory VSPH boilers: identical NON-condensing cast-iron direct-vent design, 3" AL29-4C stainless venting and 50 psi ASME MAWP. The VSPH-90 fires 90,000 Btuh across 4 sections against the VSPH-60's 60,000 Btuh across 3 sections, and its flue allowance holds at 40 ft below 7,500 ft, dropping to 35 ft above — the 60 stays at 40 ft at all altitudes.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Slant/Fin VSPH-60 and Slant/Fin VSPH-90
SpecificationSlant/Fin VSPH-60Slant/Fin VSPH-90
Input60 MBH90 MBH
Cast-iron sections34
VentingDirect vent, sealed combustion — mechanically induced draft, positive-pressure flue: 3" diameter UL-listed AL29-4C stainless steel only (Heat-Fab Saf-T Vent / Saf-T EZ Seal, ProTech FasNSeal, Flex-L StaR-34 or Z-Flex Z-Vent); NO PVC/plastic or galvanized flue; no vent damper; common venting not allowedDirect vent, sealed combustion — mechanically induced draft, positive-pressure flue: 3" diameter UL-listed AL29-4C stainless steel only (Heat-Fab Saf-T Vent / Saf-T EZ Seal, ProTech FasNSeal, Flex-L StaR-34 or Z-Flex Z-Vent); NO PVC/plastic or galvanized flue; no vent damper; common venting not allowed
Max. flue equivalent length (Heat-Fab Saf-T / EZ Seal)40 ft at all altitudes40 ft (0–7,500 ft) / 35 ft (7,500–10,000 ft)
FuelNatural gas or propaneNatural gas or propane
Maximum allowable working pressure (MAWP)50 psi50 psi
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect water heater (indirect connections supported by the control)Heating-only boiler — domestic hot water comes from a separate indirect water heater (indirect connections supported by the control)

What actually separates them

Both are cast-iron, NON-condensing, floor-standing direct-vent boilers of the discontinued Victory VSPH series, with mechanically induced draft and a positive-pressure flue that must be 3" UL-listed AL29-4C stainless steel — no PVC, no vent damper, no common venting. Each runs the HydroStat 3000 control at 50 psi ASME MAWP with a 30 psi relief valve on natural gas or field-converted LP.

The VSPH-90 raises the fixed input from 60,000 to 90,000 Btuh and the section count from 3 to 4. Jacket width (A) grows from 11-1/8" to 14-1/8" and dimension B from 17-3/8" to 20-3/8" per the I&O manual's Figure 1.

Flue allowances differ by size above 7,500 ft: on Heat-Fab Saf-T / EZ Seal systems the VSPH-60 is allowed 40 ft at all altitudes to 10,000 ft, while the VSPH-90 is allowed 40 ft to 7,500 ft and 35 ft from 7,500–10,000 ft (both keep a 40 ft air intake). Other listed vent systems print shorter runs for each size.

DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Slant/Fin Victory VSPH-60 is the smallest VSPH: a discontinued, NON-condensing cast-iron, floor-standing direct-vent boiler with 60,000 Btuh fixed input across 3 cast-iron sections, venting in 3" AL29-4C stainless steel to 40 ft at all altitudes.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
—
Output (max)
—
AFUE
—

The Slant/Fin Victory VSPH-90 fires 90,000 Btuh fixed input across 4 cast-iron sections: a discontinued, NON-condensing, floor-standing direct-vent boiler venting in 3" AL29-4C stainless steel to 40 ft of flue below 7,500 ft.

Natural gasPropaneHeating-only

Frequently asked questions

Which VSPH size is bigger?

The VSPH-90: 90,000 Btuh fixed input across 4 cast-iron sections against the VSPH-60's 60,000 Btuh across 3 sections, with jacket width (A) of 14-1/8" versus 11-1/8".

Are both boilers condensing?

No. Both are non-condensing cast-iron direct-vent boilers that must vent in 3" AL29-4C stainless steel.

Do their flue limits differ?

Yes, above 7,500 ft: the VSPH-60 is allowed 40 ft at all altitudes while the VSPH-90 drops from 40 ft to 35 ft from 7,500–10,000 ft on Saf-T / EZ Seal systems.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.