Slant/Fin · Victory VSPH

Slant/Fin VSPH-60

The Slant/Fin Victory VSPH-60 is the smallest VSPH: a discontinued, NON-condensing cast-iron, floor-standing direct-vent boiler with 60,000 Btuh fixed input across 3 cast-iron sections, venting in 3" AL29-4C stainless steel to 40 ft at all altitudes.

DiscontinuedCanadian status unknown

Key figures

Max input
60 MBH
Max CSA output
—
AFUE
—
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Slant/Fin VSPH-60 in practice

The VSPH-60 is the entry size of the Victory VSPH series — a cast-iron, gas-fired, floor-standing boiler that is NOT condensing and NOT wall-hung. It fires a fixed 60,000 Btuh across 3 cast-iron sections (metal push nipples, ASME 'H' stamp) in a mechanically induced-draft, sealed-combustion direct-vent design whose positive-pressure flue must be 3" UL-listed AL29-4C stainless steel. Its jacket width (A) is 11-1/8" with dimension B 17-3/8" per the manual's Figure 1 (+1-1/2" height and 28-1/2" depth with the combustible floor kit).

The I&O venting table allows 40 ft maximum equivalent flue length on Heat-Fab Saf-T / EZ Seal systems at all altitudes to 10,000 ft for this size (air intake 40 ft), with shorter runs on other listed systems such as ProTech FasNSeal (30 ft). The HydroStat 3000 control (DOE-2012 compliant, LED diagnostics) runs the burner on natural gas or field-converted LP, at 50 psi ASME MAWP with a 30 psi relief valve.

Slant/Fin lists the VSPH under 'Vintage' and the line is discontinued, and the official library page hosts 2018 heat-exchanger RECALL notices — owners of a VSPH-60 must check those notices for their unit's date range. canadianStatus stays 'unknown' (no official Canadian-sales statement found); all gas, venting and combustion work belongs with a licensed contractor.

Best suited to

  • Smaller homes with a 60,000 Btuh-class direct-vent load already installed and vented in stainless steel
  • Owners of an installed VSPH-60 confirming ratings and the recall status of their unit
  • Contractors documenting the discontinued cast-iron direct-vent generation

Applicability and support

Model number
VSPH-60
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Slant/Fin. Units are shown with every value; notes flag conflicting sources or missing figures.

Slant/Fin VSPH-60 specifications
SpecificationValueNote
Input
Input60 MBH60,000 Btuh fixed gas input per the ratings and dimensions data in the VSPH I&O manual (Pub. VSPH-41 Rev. C).
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect water heater (indirect connections supported by the control)
Venting and air
VentingDirect vent, sealed combustion — mechanically induced draft, positive-pressure flue: 3" diameter UL-listed AL29-4C stainless steel only (Heat-Fab Saf-T Vent / Saf-T EZ Seal, ProTech FasNSeal, Flex-L StaR-34 or Z-Flex Z-Vent); NO PVC/plastic or galvanized flue; no vent damper; common venting not allowedMinimum flue length 2 ft; max equivalent lengths by model and vent-system manufacturer. Combustion air intake: 3" PVC Schedule 40 or galvanized steel. Flue gas may partially condense in the blower discharge — the boiler has a factory condensate drain and water trap.
Max. flue equivalent length (Heat-Fab Saf-T / EZ Seal)40 ft at all altitudesBy elevation band 0–5,000 / 5,000–7,500 / 7,500–10,000 ft per the I&O manual's venting table; other listed systems allow shorter runs (e.g. ProTech FasNSeal).
Physical and connections
Cast-iron sections3Cast-iron sections assembled with metal push nipples (ASME 'H' stamp), per the VSPH I&O manual Figure 1.
Operating limits and other
FuelNatural gas or propaneField-convertible NG-to-LP gas valve; orifice chart covers elevations to 10,000 ft (4% derate per 1,000 ft).
Maximum allowable working pressure (MAWP)50 psi50 psi ASME working pressure with a factory-supplied 30 psi safety relief valve, per the VSPH master specification.

Frequently asked questions

Is the VSPH-60 a condensing boiler?

No. It is a non-condensing cast-iron boiler with a mechanically induced-draft, sealed-combustion direct-vent flue in 3" AL29-4C stainless steel; the factory condensate drain handles partial condensation in the blower discharge.

How much does the VSPH-60 input?

60,000 Btuh fixed input (60 MBH) across 3 cast-iron sections, per the VSPH I&O manual.

Was the VSPH-60 recalled?

Slant/Fin's official library hosts 2018 VSPH recall notices (contractor and homeowner) covering a heat-exchanger recall; owners should check whether their serial/date range is affected.

Questions about the Slant/Fin VSPH-60?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate