Slant/Fin VSPH-90

The Slant/Fin Victory VSPH-90 fires 90,000 Btuh fixed input across 4 cast-iron sections: a discontinued, NON-condensing, floor-standing direct-vent boiler venting in 3" AL29-4C stainless steel to 40 ft of flue below 7,500 ft.

DiscontinuedCanadian status unknown

Key figures

Max input
90 MBH
Max CSA output
—
AFUE
—
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Slant/Fin VSPH-90 in practice

The VSPH-90 is the second Victory VSPH size: a cast-iron, gas-fired, floor-standing boiler that is NOT condensing, firing a fixed 90,000 Btuh across 4 cast-iron sections. It is mechanically induced draft with a sealed-combustion, direct-vent, positive-pressure flue in 3" UL-listed AL29-4C stainless steel — no PVC/plastic or galvanized flue, no vent damper, no common venting. Its jacket width (A) is 14-1/8" with dimension B 20-3/8" per the manual's Figure 1 (+1-1/2" height and 28-1/2" depth with the combustible floor kit).

The I&O venting table allows 40 ft maximum equivalent flue length on Heat-Fab Saf-T / EZ Seal systems to 7,500 ft elevation, dropping to 35 ft from 7,500–10,000 ft (air intake 40 ft at all altitudes); other listed systems such as Z-Flex Z-Vent (35/35/30 ft) and ProTech FasNSeal (30/30/25 ft) allow less. The HydroStat 3000 control manages natural gas or field-converted LP firing at 50 psi ASME MAWP with a 30 psi relief valve.

The VSPH line is discontinued and listed under 'Vintage' on Slant/Fin's library, which also hosts 2018 heat-exchanger RECALL notices — owners of a VSPH-90 must check those notices for their unit's date range. canadianStatus stays 'unknown'; licensed-contractor work applies to gas, venting and combustion.

Best suited to

  • Homes whose direct-vent load fits a fixed 90,000 Btuh input in an installed VSPH
  • Owners confirming VSPH-90 ratings, vent-run limits and recall status
  • Documenting the mid-range of the discontinued cast-iron direct-vent series

Applicability and support

Model number
VSPH-90
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Slant/Fin. Units are shown with every value; notes flag conflicting sources or missing figures.

Slant/Fin VSPH-90 specifications
SpecificationValueNote
Input
Input90 MBH90,000 Btuh fixed gas input per the ratings and dimensions data in the VSPH I&O manual (Pub. VSPH-41 Rev. C).
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect water heater (indirect connections supported by the control)
Venting and air
VentingDirect vent, sealed combustion — mechanically induced draft, positive-pressure flue: 3" diameter UL-listed AL29-4C stainless steel only (Heat-Fab Saf-T Vent / Saf-T EZ Seal, ProTech FasNSeal, Flex-L StaR-34 or Z-Flex Z-Vent); NO PVC/plastic or galvanized flue; no vent damper; common venting not allowedMinimum flue length 2 ft; max equivalent lengths by model and vent-system manufacturer. Combustion air intake: 3" PVC Schedule 40 or galvanized steel. Flue gas may partially condense in the blower discharge — the boiler has a factory condensate drain and water trap.
Max. flue equivalent length (Heat-Fab Saf-T / EZ Seal)40 ft (0–7,500 ft) / 35 ft (7,500–10,000 ft)By elevation band 0–5,000 / 5,000–7,500 / 7,500–10,000 ft per the I&O manual's venting table; other listed systems allow shorter runs (e.g. ProTech FasNSeal).
Physical and connections
Cast-iron sections4Cast-iron sections assembled with metal push nipples (ASME 'H' stamp), per the VSPH I&O manual Figure 1.
Operating limits and other
FuelNatural gas or propaneField-convertible NG-to-LP gas valve; orifice chart covers elevations to 10,000 ft (4% derate per 1,000 ft).
Maximum allowable working pressure (MAWP)50 psi50 psi ASME working pressure with a factory-supplied 30 psi safety relief valve, per the VSPH master specification.

Frequently asked questions

How does the VSPH-90 compare with the VSPH-60?

Input rises from 60,000 to 90,000 Btuh and the section count from 3 to 4; jacket width (A) grows from 11-1/8" to 14-1/8" and dimension B from 17-3/8" to 20-3/8".

What flue length does the VSPH-90 allow?

40 ft maximum equivalent on Heat-Fab Saf-T / EZ Seal to 7,500 ft and 35 ft from 7,500–10,000 ft; other listed vent systems allow shorter runs.

Does the VSPH-90 produce domestic hot water?

No — it is heating-only; domestic hot water comes from a separate indirect water heater.

Questions about the Slant/Fin VSPH-90?