Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Weil-McLain Evergreen EVG-155 vs EVG-220

Verdict in brief

The EVG-220 crosses onto the 220-399 Evergreen platform: turndown doubles from 5:1 to 10:1, venting becomes 3"-or-4", the altitude allowance drops from 5,500 to 2,000 ft, and connections step to 1-1/2" NPT with 3/4" gas — in exchange for 65 MBH of extra input over the 155.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Weil-McLain Evergreen EVG-155 and Weil-McLain Evergreen EVG-220
SpecificationWeil-McLain Evergreen EVG-155Weil-McLain Evergreen EVG-220
Input, maximum155 MBH220 MBH
DOE heating capacity143 MBH206 MBH
Net AHRI water rating124 MBH179 MBH
Efficiency (AFUE)95.1 %95 %
Turndown5:110:1
Weight145 lb215 lb
Boiler water content3.2 gal4.6 gal
Venting3" PVC, CPVC, polypropylene or AL29-4C stainless steel (Category IV); 3" pipe only on the 1553" (with reducer) or 4" PVC, CPVC, polypropylene or AL29-4C stainless steel (Category IV)

What actually separates them

The EVG-155 and EVG-220 sit on opposite sides of the Evergreen platform split: the 155 is the last size of the 110-155 platform (manual 550-100-210/D_1222, 3" venting only, 5:1 turndown), while the 220 opens the 220-399 platform (manual 550-100-211/0122, 3"-or-4" venting, 10:1 turndown).

Efficiency stays essentially level — 95.1% AFUE on the 155 against 95.0% on the 220 — so the differences are capacity and installation: the 220 fires 220 MBH for 206 MBH of DOE heating capacity, holds 4.6 gallons against 3.2, ships at 215 lb against 145 lb, and needs 1-1/2" NPT supply and return tappings with 3/4" NPT gas.

The 220's altitude note also changes — no modifications only to 2,000 ft, versus 5,500 ft on the 110-155 platform. Choose the 220 when the heat-loss calculation exceeds what the 155's 143 MBH of output can carry; otherwise the 155 is the lighter, simpler installation.

CurrentSold in Canada
Input
—
Output (max)
143 MBH
AFUE
95.1 %

The Evergreen EVG-155 is the highest-rated Evergreen at 95.1% AFUE: 155 MBH input, 143 MBH DOE heating capacity and a 124 MBH net AHRI rating, still on 3" venting and the 5:1-turndown 110-155 platform.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
—
Output (max)
206 MBH
AFUE
95 %

The Evergreen EVG-220 is the first of the larger Evergreen platform: 220 MBH input, 206 MBH DOE heating capacity at 95.0% AFUE, modulating 10:1 and vented in 3" or 4" pipe.

Natural gasPropaneHeating-only

Frequently asked questions

Do the 155 and 220 share a manual?

No. The EVG-155 is covered by the 110/155 manual (550-100-210/D_1222) and the EVG-220 by the 220-399 manual (550-100-211/0122).

What changes at the 220 size?

Turndown moves from 5:1 to 10:1, venting from 3"-only to 3"-or-4", connections to 1-1/2" NPT with 3/4" gas, and the no-altitude-modification allowance shortens from 5,500 to 2,000 ft.

Which is more efficient?

The EVG-155 is rated 95.1% AFUE against 95.0% on the EVG-220 — a marginal difference compared with matching capacity to the load.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.