Weil-McLain Evergreen EVG-220
The Evergreen EVG-220 is the first of the larger Evergreen platform: 220 MBH input, 206 MBH DOE heating capacity at 95.0% AFUE, modulating 10:1 and vented in 3" or 4" pipe.
Key figures
- Max input
- 220 MBH
- Max CSA output
- 206 MBH
- AFUE
- 95 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Weil-McLain Evergreen EVG-220 in practice
The EVG-220 moves the Evergreen onto the 220-399 platform covered by boiler manual 550-100-211/0122: 220 MBH CSA input, 206 MBH DOE heating capacity, a 179 MBH net AHRI rating and 95.0% AFUE, with turndown stepping from the 110-155 models' 5:1 to 10:1.
Venting offers a choice of 3" pipe (with a reducer) or 4" to 100 feet each for vent and air, and the 220-399 manuals call for no altitude modifications up to 2,000 ft. Water and gas connections step up to 1-1/2" NPT and 3/4" NPT respectively, and the boiler holds 4.6 gallons of water with a 215 lb shipping weight — floor-standing is the norm, with a wall-mount kit optional.
Best suited to
- Large homes and small commercial-style loads in the 180-220 MBH band
- Projects whose vent route fits 3" pipe with a reducer or runs 4"
- Multi-zone systems that use Evergreen's presets and 24-zone capacity
Applicability and support
- Model number
- EVG-220
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, maximum | 220 MBH | CSA input: 220,000 BTU/h. |
| Output | ||
| DOE heating capacity | 206 MBH | DOE heating capacity at maximum input; the manuals also call this CSA Output. |
| Net AHRI water rating | 179 MBH | Net AHRI rating per the boiler manual ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE (DOE seasonal efficiency). |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler; domestic hot water via an indirect tank or separate appliance | |
| Venting and air | ||
| Venting | 3" (with reducer) or 4" PVC, CPVC, polypropylene or AL29-4C stainless steel (Category IV) | Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit. |
| Max. equivalent vent/air length | 100 ft vent and 100 ft air | |
| Physical and connections | ||
| Weight | 215 lb | Approx. shipping weight per the brochure. |
| Gas connection | 3/4" NPT | |
| Heating water connections | 1-1/2" NPT | Supply and return tappings 1-1/2" on the 220; minimum recommended pipe 1-1/4". |
| Operating limits and other | ||
| Turndown | 10:1 | 10:1 turndown for the 220-399 sizes per the brochure and submittal. |
| Boiler water content | 4.6 gal | |
| Altitude rating | 2,000 ft | No modifications from sea level to 2,000 ft; auto-derate of about 4% per 1,000 ft above sea level. |
| Fuel | Natural gas or propane | Propane requires a conversion kit per the CA product page. |
Manuals
- Evergreen Boiler Manual — Sizes 220/299/300/399, 550-100-211/0122550-100-211/0122 · 2022-01
Alerts documented for this model
- Nothing shown on display screen and boiler will not respond to call for heat
- Nothing is shown in display screen and no other boiler components are operating
- Nothing is shown on display screen, but boiler is operating
- TEMP RISE TOO QUICKLY
- DISPLAY COMM Fault
- Hardware Fault
- LOW WTR CUTOFF OPEN
- SUPPLY 58° F > RETURN
- RETURN > SUPPLY
- SUPPLY WATER TEMPERATURE TOO HIGH
- TEMPERATURE SENSOR FAULT
- FLUE TEMP TOO HIGH
- LIMIT OPEN
- HIGH TEMP LIMIT
- FLAME FAULT
- GAS VALVE FAULT
- BLOWER FAULT
- IGNITION FAULT
- OUTDOOR SENSOR ERROR
- AIR PRESSURE Switch Open
- Closure Switch fault
Frequently asked questions
What platform is the EVG-220 on?
It is the entry size of the 220-399 Evergreen platform documented by boiler manual 550-100-211/0122, with 10:1 turndown and 3" or 4" venting.
What are the EVG-220's ratings?
220 MBH input, 206 MBH DOE heating capacity, 179 MBH net AHRI and 95.0% AFUE.
Can the EVG-220 be wall-mounted?
Yes — a wall-mount kit is optional for the 220-399 sizes; the boiler ships floor-standing with adjustable legs.
Questions about the Weil-McLain Evergreen EVG-220?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
Sources and verification
- Weil-McLain Canada — Evergreen · accessed September 7, 2026
- Evergreen Boiler Manual 550-100-211/0122 (220-399) · 550-100-211/0122 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.