Weil-McLain Evergreen EVG-155
The Evergreen EVG-155 is the highest-rated Evergreen at 95.1% AFUE: 155 MBH input, 143 MBH DOE heating capacity and a 124 MBH net AHRI rating, still on 3" venting and the 5:1-turndown 110-155 platform.
Key figures
- Max input
- 155 MBH
- Max CSA output
- 143 MBH
- AFUE
- 95.1 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Weil-McLain Evergreen EVG-155 in practice
The EVG-155 carries the line's top DOE efficiency figure — 95.1% AFUE — at 155 MBH CSA input, with 143 MBH of DOE heating capacity and a 124 MBH net AHRI rating. It stays on the 110-155 platform: 3" vent/air piping only, 5:1 turndown, and no altitude modifications to 5,500 ft.
Connections step up from the 110: the supply and return tappings are 1-1/4" NPT with 1-1/4" minimum recommended pipe, while the gas connection stays at 1/2" NPT. As a heating-only boiler it works with an indirect tank for domestic hot water, and it can stand on the floor or mount on the wall within the 110-155 cabinet.
Best suited to
- Homes whose heat-loss calculation reaches 120-150 MBH
- Buyers after the highest AFUE number in the Evergreen range
- Projects with 3" venting routes to 100 ft
Applicability and support
- Model number
- EVG-155
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, maximum | 155 MBH | CSA input: 155,000 BTU/h. |
| Output | ||
| DOE heating capacity | 143 MBH | DOE heating capacity at maximum input; the manuals also call this CSA Output. |
| Net AHRI water rating | 124 MBH | Net AHRI rating per the boiler manual ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 95.1 % | 95.1% AFUE (DOE seasonal efficiency) — the highest AFUE in the Evergreen line. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler; domestic hot water via an indirect tank or separate appliance | |
| Venting and air | ||
| Venting | 3" PVC, CPVC, polypropylene or AL29-4C stainless steel (Category IV); 3" pipe only on the 155 | Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit. |
| Max. equivalent vent/air length | 100 ft vent and 100 ft air | |
| Physical and connections | ||
| Weight | 145 lb | Approx. shipping weight per the brochure; the manual lists 142 lb shipping / 129 lb operating. |
| Gas connection | 1/2" NPT | |
| Heating water connections | 1-1/4" NPT | Supply and return tappings 1-1/4" on the 155; minimum recommended pipe 1-1/4". |
| Operating limits and other | ||
| Turndown | 5:1 | 5:1 turndown for the 110-155 sizes per the brochure and submittal. |
| Boiler water content | 3.2 gal | 3.22 gallons per the boiler manual. |
| Altitude rating | 5,500 ft | No modifications from sea level to 5,500 ft; auto-derate of about 4% per 1,000 ft above sea level. |
| Fuel | Natural gas or propane | Propane requires a conversion kit per the CA product page. |
Manuals
- Evergreen Boiler Manual — Sizes 110/155, 550-100-210/D_1222550-100-210/D_1222 · 2022-12
Alerts documented for this model
- Nothing shown on display screen and boiler will not respond to call for heat
- Nothing is shown in display screen and no other boiler components are operating
- Nothing is shown on display screen, but boiler is operating
- TEMP RISE TOO QUICKLY
- DISPLAY COMM Fault
- Hardware Fault
- LOW WTR CUTOFF OPEN
- SUPPLY 58° F > RETURN
- RETURN > SUPPLY
- SUPPLY WATER TEMPERATURE TOO HIGH
- TEMPERATURE SENSOR FAULT
- FLUE TEMP TOO HIGH
- LIMIT OPEN
- HIGH TEMP LIMIT
- FLAME FAULT
- GAS VALVE FAULT
- BLOWER FAULT
- IGNITION FAULT
- OUTDOOR SENSOR ERROR
- AIR PRESSURE Switch Open
- Closure Switch fault
Frequently asked questions
Why is the EVG-155 rated higher than the rest of the line?
Its DOE seasonal efficiency is 95.1% AFUE against 95.0% for the 110, 220 and 299; the brochure notes the 399's 96.5% figure is combustion efficiency, not AFUE.
What venting does the EVG-155 need?
3" pipe only — PVC, CPVC, polypropylene or AL29-4C stainless — to 100 feet each for vent and air, per the boiler manual.
Does the EVG-155 produce domestic hot water?
No. It is heating-only and is designed to work with an indirect-fired water heater for hot water.
Questions about the Weil-McLain Evergreen EVG-155?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
Sources and verification
- Weil-McLain Canada — Evergreen · accessed September 7, 2026
- Evergreen Boiler Manual 550-100-210/D_1222 (110/155) · 550-100-210/D_1222 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.