Skip to content
Boilers.caby ROMA Heating & Cooling

Crown Boiler Co. · Bimini (legacy)

Crown Bimini BWC120

The Crown Bimini BWC120 is the 120-MBH-class model of the Sola-control BWC generation (suffix EN for natural gas, EL for propane): an aluminum, wall-hung, direct-vent condensing boiler firing 40–120 MBH with 107 MBH DOE heating capacity and a 93 MBH net water rating.

DiscontinuedCanadian status unknown

Key figures

Max input
120 MBH
Max CSA output
AFUE
Min input
40 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Crown Bimini BWC120 in practice

The Bimini BWC120 belongs to the Sola-control generation of Crown's legacy BWC condensing family (models BWC070/090/120/151 documented in the Sola-generation installation manual). Its specification-table row prints a 120/40 MBH maximum/minimum input, 107 MBH DOE heating capacity and a 93 MBH net water rating, with 0.62 US gallons of water volume, 1" NPT supply/return connections, a 1/2" NPT gas connection and an approximate net weight of 110 lb.

The boiler is an aluminum gas condensing design for forced hot water systems at supply temperatures of 180°F or less, designed for installation on a wall with an optional pedestal kit for floor mounting, and it vents directly with the supplied concentric system or approved 3" AL29-4C stainless venting. Add the suffix EN for natural gas or EL for propane — ratings are the same for both fuels per the manual's table note.

The Bimini is legacy: it appears only in the frozen crownboiler.com navigation and is absent from the current Velocity Boiler Works menu, so productStatus is 'discontinued'. The manual prints no AFUE figure, so none is stated here. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; service work belongs with a licensed contractor.

Best suited to

  • Owners documenting an installed Sola-generation Bimini against the legacy manual
  • Contractors researching the BWC070/090/120/151 model set and its venting limits
  • Legacy-replacement planning where the boiler's rating-plate generation must be matched

Applicability and support

Model number
BWC120
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.

Crown Bimini BWC120 specifications
SpecificationValueNote
Input
Input, maximum120 MBHMaximum input per the BWC specification table (Table 2.2, Sola-generation installation manual).
Input, minimum40 MBHMinimum input per the BWC specification table (Table 2.2).
Output
DOE heating capacity107 MBHDOE heating capacity per the BWC specification table (Table 2.2).
Net water rating93 MBHAHRI net water rating per the BWC specification table (Table 2.2).
Efficiency
EfficiencyNot printed in the sourced manualThe BWC Sola-generation installation manual does not print an AFUE figure; Boilers.ca does not state one.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
VentingDirect vent — concentric or approved stainless systemsSola-generation manual covers the supplied concentric vent system (25 ft), optional 60/100mm components (18–32 ft by model), 80/125mm vertical (95 ft) or horizontal (100 ft) concentric systems, and approved 3" AL29-4C horizontal stainless venting to 100 ft (Table 2.3).
Physical and connections
Water volume0.62 galBoiler water volume per the BWC specification table (Table 2.2).
Supply and return connections1" NPTSupply and return connection size per the BWC specification table (Table 2.2).
Gas connection1/2" NPTGas connection size per the BWC specification table (Table 2.2).
Approx. net weight110 lbApproximate net weight per the BWC specification table (Table 2.2).
Operating limits and other
ControlHoneywell Sola controlText-diagnostics control per the Sola-generation installation manual.
FuelNatural gas or propaneAdd suffix EN for natural gas and EL for propane; ratings are the same for both fuels (Table 2.2 note).

Frequently asked questions

What are the BWC120's ratings?

40–120 MBH minimum/maximum input with 107 MBH DOE heating capacity and a 93 MBH net water rating per the BWC specification table (Table 2.2).

What does the EN/EL suffix mean?

Add EN for natural gas or EL for propane to the base model number; the manual states ratings are the same for both fuels.

Was the BWC120 a combi boiler?

No — the Bimini produced space heating only. Domestic water came from a separate tank (the 'Bimini Buddy' add-on documented as an accessory), not from the boiler.

Questions about the Crown Bimini BWC120?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate