Crown Boiler Co. · Bimini (legacy)
Crown Bimini BWC150
The Crown Bimini BWC150 is the 150-MBH-class floor model of the MCBA-control BWC generation (LP suffix for propane): an aluminum condensing boiler firing 50–150 MBH with 133 MBH DOE heating capacity and a 117 MBH net water rating over 3 sections, with a 4" vent-collar inlet and 3" exhaust collar.
Key figures
- Max input
- 150 MBH
- Max CSA output
- —
- AFUE
- —
- Min input
- 50 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Crown Bimini BWC150 in practice
The Bimini BWC150 belongs to the MCBA-control generation of Crown's legacy BWC condensing family (the later floor models BWC150/BWC225 documented in the MCBA-generation installation manual). Its specification-table row prints a 150/50 MBH maximum/minimum input, 133 MBH DOE heating capacity and a 117 MBH net water rating over 3 sections, with a 4" vent-collar inlet and 3" exhaust collar.
The BWC boilers use aluminum heat exchangers constructed, tested and stamped in accordance with ASME Boiler and Pressure Vessel Code Case 2382-2 per the installation manual, which notes some jurisdictions do not recognize that Code Case. Models shown are for natural gas; add the LP suffix for propane (for example BWC225LP) and performance ratings are the same for both fuels.
The Bimini is legacy: it appears only in the frozen crownboiler.com navigation and is absent from the current Velocity Boiler Works menu, so productStatus is 'discontinued'. The manual prints no AFUE figure, so none is stated here. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; service work belongs with a licensed contractor.
Best suited to
- Owners documenting an installed MCBA-generation Bimini against the correct manual
- Contractors researching the BWC150/BWC225 floor models and their vent collars
- Legacy-replacement planning where the rating-plate generation must be matched
Applicability and support
- Model number
- BWC150
- Canadian availability
- unknown
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, maximum | 150 MBH | Maximum input per the BWC specification table (Table 2.2, MCBA-generation installation manual). |
| Input, minimum | 50 MBH | Minimum input per the BWC specification table (Table 2.2). |
| Output | ||
| DOE heating capacity | 133 MBH | DOE heating capacity per the BWC specification table (Table 2.2). |
| Net water rating | 117 MBH | AHRI net water rating per the BWC specification table (Table 2.2). |
| Efficiency | ||
| Efficiency | Not printed in the sourced manual | The MCBA-generation installation manual does not print an AFUE figure; Boilers.ca does not state one. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | |
| Venting and air | ||
| Vent collar diameters | Inlet 4", exhaust 3" | Vent collar inlet and exhaust diameters per the BWC specification table (Table 2.2). |
| Physical and connections | ||
| Sections | 3 | Number of sections per the BWC specification table (Table 2.2). |
| Operating limits and other | ||
| Control | MCBA control | MCBA-generation control with soft-lockout (b-code) and hard-lockout (E-code) displays per the installation manual. |
| Fuel | Natural gas or propane | Models shown are for natural gas; add the LP suffix for propane (e.g. BWC225LP); performance ratings are the same for both fuels. |
Alerts documented for this model
Frequently asked questions
What are the BWC150's ratings?
50–150 MBH minimum/maximum input with 133 MBH DOE heating capacity and a 117 MBH net water rating per the BWC specification table (Table 2.2).
How do I order the propane version?
Add the LP suffix to the model number (e.g. BWC225LP); the manual states performance ratings are the same for both fuels.
Which manual covers the BWC150 and BWC225?
The MCBA-generation installation manual (Bimini_BWC_Installation_Manual.pdf on crownboiler.com); the Sola-generation manual covers BWC070–BWC151 and must not be mixed with this generation.
Questions about the Crown Bimini BWC150?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.