Crown Boiler Co. · Error codes
Crown Aruba E 12 — Low Water Cut-off Circuit Open
E 12
Low water cut-off circuit open. If yellow light on LWCO is on, system is low on water; if neither yellow nor green light is on, check LWCO harness and check for 24 VAC across AT140 transformer The table classifies it as hard lockout.
Applies to
This low-water or pressure protection code is displayed by the Bimini control on Bimini BWC models (BWC150, BWC225 and earlier Sola generation), as documented in Bimini Residential (BWC) Installation Instructions (legacy Crown manual). Codes can differ between controller generations, so always check the manual that matches your unit.
- Crown Boiler Co. Bimini (legacy)
- Crown Bimini BWC070
- Crown Bimini BWC090
- Crown Bimini BWC120
- Crown Bimini BWC151
- Crown Bimini BWC150
- Crown Bimini BWC225
Controller: Bimini control. Source manual: see sources.
Why a code is not a diagnosis
A water-pressure or low-water code can mean a genuine leak or empty system, a failed expansion tank, a faulty fill valve, or a sensor problem. The appliance does not distinguish these.
Safe things to observe
- Read the pressure gauge and compare it with the normal cold-system pressure your installer set.
- Look for drips or wet spots near the appliance, pipes and the relief-valve discharge.
Do not
- Do not keep re-pressurizing a system that keeps losing water.
- Do not cap a relief-valve discharge pipe.
How professional service helps
- A technician finds and repairs the leak, checks the expansion tank and fill assembly, and verifies the sensor circuit.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Transformer
The transformer is the small component inside the boiler that steps household 120-volt power down to the low voltage the controls use — typically 24…
What a technician checks →Low-water cutoff
A low-water cutoff is the safety device that stops a boiler from firing when there is not enough water inside it.
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
- Emergency Boiler Repair
Priority gas boiler repair for homes and buildings in Greater Vancouver with no heat, no hot water, a locked-out boiler or a leak.
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for Crown Boiler Co. Bimini (legacy).
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Bimini Residential (BWC) Installation Instructions (legacy Crown manual) · accessed September 8, 2026
Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.