HTP Elite FT PRO — Low Water Pressure
PRO
Low water pressure. Low water pressure in the boiler. Assure the system pressure is above 10 psig and check for leaks in the system piping; the code resets automatically once pressure is high enough for the boiler to run safely. The second line indicates pump status; the pump is off while pressure is low. The table classifies it as Blocking (Auto Reset).
Applies to
This low-water or pressure protection code is displayed by the 926 SIT control on Elite FT models (EFT-55 through EFT-399), as documented in Elite FT Installation Manual, LP-387 Rev. 011 Rel. 009 (2.19.21), Table 31 (LP-387). Codes can differ between controller generations, so always check the manual that matches your unit.
- HTP Elite FT (EFT) (discontinued)
- HTP EFT-55
- HTP EFT-80
- HTP EFT-110
- HTP EFT-155
- HTP EFT-199
- HTP EFT-285
- HTP EFT-399
Controller: 926 SIT control. Source manual: LP-387.
Why a code is not a diagnosis
A water-pressure or low-water code can mean a genuine leak or empty system, a failed expansion tank, a faulty fill valve, or a sensor problem. The appliance does not distinguish these.
Safe things to observe
- Read the pressure gauge and compare it with the normal cold-system pressure your installer set.
- Look for drips or wet spots near the appliance, pipes and the relief-valve discharge.
Do not
- Do not keep re-pressurizing a system that keeps losing water.
- Do not cap a relief-valve discharge pipe.
How professional service helps
- A technician finds and repairs the leak, checks the expansion tank and fill assembly, and verifies the sensor circuit.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Low-water cutoff
A low-water cutoff is the safety device that stops a boiler from firing when there is not enough water inside it.
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for HTP Elite FT (EFT) (discontinued).
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Elite FT Installation Manual, LP-387 Rev. 011 Rel. 009 (2.19.21), Table 31 · LP-387 · accessed September 8, 2026