Skip to content
Boilers.caby ROMA Heating & Cooling

HTP · Series

HTP Elite FT (EFT) (discontinued)

The Elite FT (EFT) is HTP's retired stainless steel fire-tube condensing boiler line: seven models EFT-55 through EFT-399 with 11,000-399,000 BTU/hr printed input ranges, a vertical fire-tube heat exchanger, 5:1 turndown on the 55-199 generation and 10:1 on the later 285/399, cascade support for up to eight boilers and a 12-year heat-exchanger warranty.

discontinuedunknownNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
96.3% AFUE
Fuel
LP-392 prints 'Models Available for Natural or LP Gas'; LP-657 adds 'Models Available for Natural or LP Gas' for the 285/399 10:1 generation.
Venting
Unknown
Models documented
7

LP-392/LP-391 print 'an AFUE rating up to 96.3% and thermal efficiency up to 93.2' for the 5:1 models. The retired page prints EFT-285 at 95.1% AFUE and EFT-399 at 97.1* thermal efficiency (as printed); LP-659 prints the same 95.1/97.1 figures for the 10:1 generation.

About the Elite FT (EFT) (discontinued)

HTP's retired Elite FT page describes 'a high efficiency heating boiler for residential and commercial applications' that 'comes in two models, ranging from 285,000 to 399,000 BTUs' with 'up to a 95.1% AFUE rating with up to a 10 to 1 turndown ratio', a stainless steel heat exchanger, 200 ft combined vent in 3" PVC, cascade support for up to eight boilers and a twelve year warranty. The printed page table lists EFT-285 at 285,000 Btu/hr, 95.1% AFUE and 203 lbs, and EFT-399 at 399,000 Btu/hr, 97.1* thermal efficiency and 298 lbs (N/A energy guide).

LP-387's technical specifications table supplies the full seven-model rating set used on the model records — inputs (11,000/55,000 through 79,800/399,000 in the 5:1 table), heating capacity (51-367 MBH), shipping weights (125-298 lb), water content, dimensions, copper SWT connections, 30 or 80 PSI MAWP and venting — while LP-657 prints the on/after-10/30/17 10:1-generation 285/399 inputs (28,500/285,000 and 39,900/399,000) used for those two model records. LP-392 prints the 5:1 generation's 'AFUE rating up to 96.3%', ASME 'H' construction, National Board listing, ETL listing, ANSI Z21.13/CSA 4.9, a 12-year heat-exchanger warranty, cascade up to eight boilers and 0-10V BMS input.

The Elite FT is retired: HTP's discontinued-products index lists 'Elite FT Heating Boiler' and the EFT documents page remains as archived support. Boilers.ca records the line with productStatus 'discontinued' and canadianStatus 'unknown' — no official Canadian sales statement was found. Owners should have the unit serviced by a licensed contractor against LP-387 (or LP-657 for the later 285/399).

Highlights

  • Retired line on HTP's official discontinued-products index
  • Seven printed models EFT-55 through EFT-399; 11,000-399,000 BTU/hr input range
  • Two generations documented: 5:1 turndown (55-199) and 10:1 turndown (285/399 mfg on/after 10/30/17)
  • Per-model rows from LP-387 Table (inputs, capacity, weight, water content, dimensions, connections) and LP-657 for 285/399
  • ASME 'H' stamped stainless fire-tube heat exchanger; cascade up to 8; 12-year heat-exchanger warranty

LP-392/LP-391 print a twelve (12) year limited warranty on the complete heat exchanger assembly; the retired page prints 'The Elite FT comes with a twelve year warranty'.

Models

Elite FT (EFT) (discontinued) models

One canonical page per model with input, output and efficiency kept separate.

DiscontinuedCanadian status unknown
Input
11–55 MBH
Output (max)
AFUE

The HTP EFT-55 is the 55 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 11,000 to 55,000 BTU/hr input, 51 MBH heating capacity, 125 lb shipping weight and a 5:1 turndown, recorded from the official LP-387 technical table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
16–80 MBH
Output (max)
AFUE

The HTP EFT-80 is the 80 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 16,000 to 80,000 BTU/hr input, 79 MBH heating capacity, 128 lb shipping weight and a 5:1 turndown, recorded from the official LP-387 technical table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
22–110 MBH
Output (max)
AFUE

The HTP EFT-110 is the 110 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 22,000 to 110,000 BTU/hr input, 102 MBH heating capacity, 130 lb shipping weight and a 5:1 turndown, recorded from the official LP-387 technical table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
31–155 MBH
Output (max)
AFUE

The HTP EFT-155 is the 155 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 31,000 to 155,000 BTU/hr input, 142 MBH heating capacity, 195 lb shipping weight and a 5:1 turndown, recorded from the official LP-387 technical table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
39.8–199 MBH
Output (max)
AFUE

The HTP EFT-199 is the 199 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 39,800 to 199,000 BTU/hr input, 183 MBH heating capacity, 198 lb shipping weight and a 5:1 turndown, recorded from the official LP-387 technical table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
28.5–285 MBH
Output (max)
AFUE

The HTP EFT-285 is the 285 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 28,500 to 285,000 BTU/hr input, 262 MBH heating capacity, 203 lb shipping weight and a 10:1 turndown, recorded from the official LP-387 technical table and the LP-657 10:1-generation table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
39.9–399 MBH
Output (max)
AFUE

The HTP EFT-399 is the 399 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 39,900 to 399,000 BTU/hr input, 367 MBH heating capacity, 298 lb shipping weight and a 10:1 turndown, recorded from the official LP-387 technical table and the LP-657 10:1-generation table.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of HTP EFT-55 and HTP EFT-80 and HTP EFT-110 and HTP EFT-155 and HTP EFT-199 and HTP EFT-285 and HTP EFT-399
SpecificationHTP EFT-55HTP EFT-80HTP EFT-110HTP EFT-155HTP EFT-199HTP EFT-285HTP EFT-399
Input rate, minimum11 MBH16 MBH22 MBH31 MBH39.8 MBH28.5 MBH39.9 MBH
Input rate, maximum55 MBH80 MBH110 MBH155 MBH199 MBH285 MBH399 MBH
output-max
afue
Turndown5:15:15:15:15:110:110:1
vent-max-3
vent-max-2
Shipping weight125 lb128 lb130 lb195 lb198 lb203 lb298 lb

Read the full comparison: HTP EFT-55 vs EFT-80

Read the full comparison: HTP EFT-80 vs EFT-110

Read the full comparison: HTP EFT-110 vs EFT-155

Read the full comparison: HTP EFT-155 vs EFT-199

Read the full comparison: HTP EFT-199 vs EFT-285

Read the full comparison: HTP EFT-285 vs EFT-399

Error codes and alerts

Elite FT (EFT) (discontinued) alerts

  • E03926 SIT control
  • TT926 SIT control
  • DHW926 SIT control
  • PRO926 SIT control
  • FLU926 SIT control
  • LOU926 SIT control
  • F00926 SIT control
  • F01926 SIT control
  • F02926 SIT control
  • F03926 SIT control
  • F04926 SIT control
  • F05926 SIT control
  • F06926 SIT control
  • F09926 SIT control
  • F10926 SIT control
  • F11926 SIT control
  • F13926 SIT control
  • F20926 SIT control
  • F31926 SIT control
  • PP926 SIT control
  • FOU926 SIT control
  • E07926 SIT control
  • E19926 SIT control

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What Elite FT models exist?

Seven printed models: EFT-55, EFT-80, EFT-110, EFT-155, EFT-199, EFT-285 and EFT-399, with inputs from 11,000-55,000 up to 39,900-399,000 BTU/hr depending on generation.

Why do EFT-285 and EFT-399 show different input ranges in different manuals?

The EFT-285/399 were built in two generations: LP-387's table prints the earlier 5:1 values (57,000/285,000 and 79,800/399,000) while LP-657 prints the on/after-10/30/17 10:1 values (28,500/285,000 and 39,900/399,000). Boilers.ca records the 10:1 values and notes the earlier table.

Is the Elite FT discontinued?

Yes — HTP's discontinued-products index lists 'Elite FT Heating Boiler'; the product page and manuals remain for support.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate