The HTP EFTC-140F is the floor-standing 140 MBH class combi of the retired EFT Combi line: 28,000 to 140,000 BTU/hr CH input, 28,000 to 140,000 BTU/hr DHW input and 93.2% printed AFUE, recorded from the official retired EFT Combi table.

DiscontinuedCanadian status unknown

Key figures

Max input
140 MBH
Max CSA output
—
AFUE
93.2 %
Min input
28 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

HTP EFTC-140F in practice

The EFTC-140F is one of the two floor-standing EFT Combi models HTP documents on its retired EFT Combi floor page. The page table prints 28,000-140,000 BTU/hr DHW input, 28,000-140,000 BTU/hr CH input and 93.2% AFUE; the LP-496 technical table adds 250 lb shipping weight, a 15.7" W x 53" H x 26.8" D cabinet, Under 15 gal storage tank, DHW flows of 7.1 / 5.5 / 3.2 GPM at 35 / 45 / 77°F rise, CH 1" NPT supply/return, DHW 3/4" NPT and a 1/2" NPT (1/2" x 3/4" bell coupling provided) gas connection.

The combi uses a 316L stainless steel fire-tube heat exchanger and a stainless steel indirect storage tank, with the 140k model's 5 to 1 turndown, CH 12-30 psi and DHW 150 psi maximum pressures, 2" (50 ft) or 3" (100 ft) sealed-combustion venting and a 10-year limited warranty out of the box. The retired wall page notes ENERGY STAR certification and low-NOx emissions.

The EFT Combination Boiler (Wall and Floor) is listed on HTP's discontinued-products index; the retired pages and the LP-520/LP-496 manuals remain for support. Boilers.ca records it with productStatus 'discontinued' and canadianStatus 'unknown'; no official Canadian sales statement was found. Gas and combustion work belongs with a licensed contractor against the model's own manual.

Best suited to

  • Identifying a retired EFT Combi already installed
  • Retrieving the official LP-520/LP-496 documentation for service planning
  • Replacement planning for a wall or floor combi with a known DHW draw

Applicability and support

Model number
EFTC-140F
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by HTP. Units are shown with every value; notes flag conflicting sources or missing figures.

HTP EFTC-140F specifications
SpecificationValueNote
Input
Central-heating input, minimum28 MBH28,000 BTU/hr as printed in LP-496 Table 4 and the retired EFT Combi floor page table.
Central-heating input, maximum140 MBH140,000 BTU/hr as printed; the 199 models ship at a 140,000 BTU/hr CH maximum and can be increased to 199,000 with a larger external pump per the manual footnote.
Efficiency
AFUE (page table)93.2 %Printed as 93.2% on the retired EFT Combi floor page table; the LP-496 technical table prints 92.7%.
Domestic hot water
DHW input, minimum28 MBH28,000 BTU/hr as printed on the retired EFT Combi page table.
DHW input, maximum140 MBH140,000 BTU/hr as printed on the retired EFT Combi page table and in the manual technical table.
DHW flow rate at 35 °F rise7.1 gpmAs printed in the manual technical table (35°F rise row).
DHW flow rate at 45 °F rise5.5 gpmAs printed in the manual technical table (45°F rise row).
DHW flow rate at 77 °F rise3.2 gpmAs printed in the manual technical table (77°F rise row).
Venting and air
Venting2" (50 ft) or 3" (100 ft), combined equivalent feetSealed-combustion direct vent / power vent; Category IV per the retired pages.
Physical and connections
Shipping weight250 lbAs printed in the manual technical table.
Dimensions (W x H x D)15.7" W x 53" H x 26.8" DAs printed in the manual technical table.
Water pressureCH 12-30 psi; DHW maximum 150 psiAs printed in the manual technical table.
Heat exchanger and tank316L stainless steel fire tube heat exchanger and stainless steel indirect storage tankStorage: Under 15 gal storage tank.
Operating limits and other
ConnectionsCH supply/return 1" NPT; DHW inlet/outlet 3/4" NPT; gas 1/2" NPT (1/2" x 3/4" bell coupling provided)As printed in the manual technical table.
ControlGTX-920C / P-920C_CB-HTPPer the manual technical table.
Turndown5:1Retired wall page: 'The 199k BTU unit has a 10 to 1 turndown ratio while the 140k unit operates at a 5 to 1 turndown ratio.'
Warranty10-year limited, no registration requiredAs printed on the retired EFT Combi page.

Frequently asked questions

Is the EFTC-140F a combi boiler?

Yes — the C code denotes the combi, and the official table prints a domestic hot water input range of 28,000 to 140,000 BTU/hr plus 7.1 GPM at a 35°F rise.

What is the AFUE of the EFTC-140F?

The retired page table prints 93.2%; the LP-496 technical table prints 92.7%.

Is the EFT Combi still sold?

No — HTP's discontinued-products index lists the EFT Combination Boiler (floor and wall) and the retired pages remain for documentation only.

Questions about the HTP EFTC-140F?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate