HTP Pioneer (discontinued)

The Pioneer is HTP's retired 55-gallon high-mass condensing heater line: four models PHR100-55, PHR130-55, PHR160-55 and PHR199-55 with 35,000-199,000 BTU/hr printed input ranges, 94-95% printed thermal efficiency, a built-in buffer tank, a five to one turndown and a 12-year limited warranty.

discontinuedunknownNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
95% thermal-efficiency
Fuel
The LP-348 submittal prints 'Fires on Natural or LP Gas with included conversion kit'.
Venting
Unknown
Models documented
4

The retired page and LP-325 Table 4 print 95% for PHR100-55, PHR160-55 and PHR199-55 and 94% for PHR130-55; the page copy says 'up to a 95% thermal efficiency rating'.

About the Pioneer (discontinued)

HTP's retired Pioneer page describes 'a 55 gallon high mass unit, available in 4 BTU ranges - 100, 130, 160, and 199K' with 'up to a 95% thermal efficiency rating and a five to one turndown ratio', a built-in buffer tank, SCAQMD Rule 1146.2 compliance and a 12 year limited warranty. The printed page table and LP-325 Table 4 both list PHR100-55 (35,000-100,000, 95%), PHR130-55 (35,000-130,000, 94%), PHR160-55 (40,000-160,000, 95%) and PHR199-55 (40,000-199,000, 95%), each with a 260 lb shipping weight.

LP-325 Table 4 supplies the rating rows used on the model records: a 55-gallon 304L stainless steel buffer tank, 23" x 56" x 34" dimensions, 1-1/4" NPT female supply/return with 3/4" NPT gas and a 1" NPT drain, a 30 PSI maximum water pressure, the 926 SIT control and venting (2" 85 ft / 3" 125 ft on the 100/130; 3" 200 ft / 4" 200 ft on the 160/199). The heat exchanger is 90/10 cupronickel primary with 800H stainless steel and cupronickel secondary tubing.

The Pioneer is retired: HTP's discontinued-products index lists 'Pioneer' and the retired page remains as documentation. Boilers.ca records the line with productStatus 'discontinued' and canadianStatus 'unknown'; no official Canadian sales statement was found. Owners should have the unit serviced by a licensed contractor against LP-325.

Highlights

  • Retired line on HTP's official discontinued-products index
  • Four printed models PHR100-55 through PHR199-55, 35,000-199,000 BTU/hr
  • 55-gallon high-mass design with built-in buffer tank; five to one turndown; 94-95% thermal efficiency
  • Per-model rows from LP-325 Table 4 (input, efficiency, weight, tank, dimensions, connections, venting)
  • 12-year limited warranty; LP-325/LP-348/LP-349 all live on htproducts.com

The retired page states the Pioneer 'is backed by a limited 12 year warranty, right out of the box! No registration is required.'

Models

Pioneer (discontinued) models

One canonical page per model with input, output and efficiency kept separate.

DiscontinuedCanadian status unknown
Input
35–100 MBH
Output (max)
AFUE

The HTP PHR100-55 is the 100 MBH class model of the retired Pioneer 55-gallon high-mass condensing heater line: 35,000 to 100,000 BTU/hr input, 95% printed thermal efficiency and a 260 lb package, recorded from the official retired Pioneer table and LP-325 Table 4.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
35–130 MBH
Output (max)
AFUE

The HTP PHR130-55 is the 130 MBH class model of the retired Pioneer 55-gallon high-mass condensing heater line: 35,000 to 130,000 BTU/hr input, 94% printed thermal efficiency and a 260 lb package, recorded from the official retired Pioneer table and LP-325 Table 4.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
40–160 MBH
Output (max)
AFUE

The HTP PHR160-55 is the 160 MBH class model of the retired Pioneer 55-gallon high-mass condensing heater line: 40,000 to 160,000 BTU/hr input, 95% printed thermal efficiency and a 260 lb package, recorded from the official retired Pioneer table and LP-325 Table 4.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
40–199 MBH
Output (max)
AFUE

The HTP PHR199-55 is the 199 MBH class model of the retired Pioneer 55-gallon high-mass condensing heater line: 40,000 to 199,000 BTU/hr input, 95% printed thermal efficiency and a 260 lb package, recorded from the official retired Pioneer table and LP-325 Table 4.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of HTP PHR100-55 and HTP PHR130-55 and HTP PHR160-55 and HTP PHR199-55
SpecificationHTP PHR100-55HTP PHR130-55HTP PHR160-55HTP PHR199-55
Input rate, minimum35 MBH35 MBH40 MBH40 MBH
Input rate, maximum100 MBH130 MBH160 MBH199 MBH
output-max
afue
Turndown5:15:15:15:1
vent-max-3
vent-max-2
Shipping weight260 lb260 lb260 lb260 lb

Read the full comparison: HTP PHR100-55 vs PHR130-55

Read the full comparison: HTP PHR130-55 vs PHR160-55

Read the full comparison: HTP PHR160-55 vs PHR199-55

Read the full comparison: HTP PHR100-55 vs HTP PHR160-55

Error codes and alerts

Pioneer (discontinued) alerts

  • Fou926 SIT control
  • E19926 SIT control
  • FLU926 SIT control
  • LEO926 SIT control
  • LOU926 SIT control
  • E03926 SIT control
  • F00926 SIT control
  • F01926 SIT control
  • F02926 SIT control
  • F03926 SIT control
  • F05926 SIT control
  • F06926 SIT control
  • F09926 SIT control
  • F10926 SIT control
  • F11926 SIT control
  • F13926 SIT control
  • pp926 SIT control
  • F31926 SIT control

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What Pioneer models exist?

Four printed models: PHR100-55, PHR130-55, PHR160-55 and PHR199-55, with modulation ranges from 35,000-100,000 up to 40,000-199,000 BTU/hr.

Is the Pioneer discontinued?

Yes — HTP's discontinued-products index lists 'Pioneer'; the retired product page and its manuals remain for documentation and support.

What is the Pioneer's turndown?

The retired page and LP-348 submittal print a five to one (5:1) turndown ratio.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate