Skip to content
Boilers.caby ROMA Heating & Cooling

IBC Technologies · Error codes

IBC SL G3 Commercial No MAC address — No Mac Address

No MAC address

Needs attentionIBC SL G3 light-commercial boilers (V-10 controller, manual 120-270E12)

No MAC address. Boiler cannot verify a valid MAC address. The table classifies it as alarm.

Applies to

This fault code is displayed by the V-10 touchscreen controller on SL G3 commercial models (SL 26-260 G3, SL 40-399 G3), as documented in SL G3 Commercial Installation & Operating Manual — SL 26-260 G3 / SL 40-399 G3, doc 120-270E12 (120-270E12). Codes can differ between controller generations, so always check the manual that matches your unit.

Controller: V-10 touchscreen controller. Source manual: 120-270E12.

Why a code is not a diagnosis

The code reports the condition the control detected; the underlying cause must be confirmed on site by a licensed technician using the manufacturer's procedure.

Safe things to observe

  • Note the exact code, when it appears and what the appliance was doing.
  • If the appliance has stopped, call a technician rather than repeatedly restarting it.
  • If you smell gas, stop, go outside and call your gas utility's emergency line or 911 before anything else.

Do not

  • Do not ignore a code that returns after a reset.

How professional service helps

  1. A licensed technician diagnoses the cause with the manufacturer's test procedure.
  2. Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Can I clear this code myself?

Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.

Boiler locked out? Call with the alert text ready.

The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate