Ideal Heating Exalt Floor Combi

The Exalt Floor Combi is Ideal Heating North America's floor-standing combi line: the 155 and 199 MBH models, 95% AFUE, 8:1 turndown, with the Caleffi 548 separator, an internal circulator and on-demand DHW at up to 5.3 GPM.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
95% AFUE
Fuel
Natural gas or propane; combi floor models ship in fuel-specific versions (IDEXFS155C / IDEXFS155CLP, IDEXFS199C / IDEXFS199CLP).
Venting
3-inch venting up to 100 equivalent feet; the 155 combi also lists 2-inch venting up to 33 feet. 3-in-1 universal vent adapter accepts PVC, polypropylene and stainless steel.
Models documented
2

95% AFUE on both combi models per the official model table.

About the Exalt Floor Combi

The Exalt Floor Combi combines the floor-standing Exalt chassis with on-demand domestic hot water. Two models are published — combi 155 and combi 199 — rated 95% AFUE with an 8:1 turndown and AHRI net ratings of 123 and 159 MBH. As with the heat-only floor models, each size ships in natural-gas or propane versions (IDEXFS155C / IDEXFS155CLP and IDEXFS199C / IDEXFS199CLP).

The DHW figures match the wall combis: 4.0 GPM at a 70°F rise on the combi 155 and 5.3 GPM on the combi 199, with 3.7 and 4.9 GPM at 75°F and 3.5 and 4.6 GPM at 80°F, a 0.5 GPM minimum flow, 150 psi maximum DHW pressure and a 150°F (65°C) DHW maximum. The floor chassis adds the Caleffi 548 separator with air elimination, the pre-installed internal circulator and left-or-right water and gas connections, in a 22 x 41 x 22 inch cabinet weighing 181 lb (155) and 191 lb (199).

Venting is 3-inch up to 100 equivalent feet, with 2-inch up to 33 feet on the 155. The CTRLMax control provides DHW priority, outdoor reset and plain-text diagnostics. The series suits homes with a mechanical-room floor and a combined heating and hot-water load inside 199 MBH — the combi replaces both a boiler and a separate DHW tank.

Highlights

  • 155 and 199 MBH floor-standing combi models; 95% AFUE each
  • On-demand DHW: 4.0 GPM (155) and 5.3 GPM (199) at a 70°F rise
  • Caleffi 548 series separator with air elimination and internal circulator included
  • 8:1 turndown; stainless steel fire-tube heat exchanger
  • DHW priority and plain-text diagnostics via CTRLMax
  • 22 x 41 x 22 inch cabinet; 181–191 lb

Ideal Advantage warranty program, as published on the Exalt product pages: Standard — 2-year parts and 10-year primary heat exchanger; Plus — 5-year parts, 2-year labour allowance and 10-year primary heat exchanger with registration; Elite — 6-year parts, 3-year labour and 12-year heat exchanger with registration, combustion analysis and hydronic system treatment.

Models

Exalt Floor Combi models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
19.375–155 MBH
Output (max)
AFUE
95 %

The Ideal Exalt Floor Combi 155 is a floor-standing combi: 19,375 to 155,000 BTU/h heating input at 95% AFUE with 4.0 GPM on-demand DHW at a 70°F rise, an included separator and circulator, in a 181 lb chassis.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
24.875–199 MBH
Output (max)
AFUE
95 %

The Ideal Exalt Floor Combi 199 is the largest floor-standing combi in the Exalt line: 24,875 to 199,000 BTU/h heating input at 95% AFUE with 5.3 GPM on-demand DHW at a 70°F rise in a 191 lb chassis.

Natural gasPropaneCombi

Compare models in this series

Comparison of Ideal Exalt Floor Combi 155 and Ideal Exalt Floor Combi 199
SpecificationIdeal Exalt Floor Combi 155Ideal Exalt Floor Combi 199
Input, minimum (NG & LP)19.375 MBH24.875 MBH
Input, maximum (NG & LP)155 MBH199 MBH
output-max
Efficiency (AFUE)95 %95 %
Turndown ratio8:18:1
Maximum vent length, 3 in100 ft100 ft
Maximum vent length, 2 in33 ft
Weight181 lb191 lb

Read the full comparison: Ideal Exalt Floor Combi 155 vs 199

Error codes and alerts

Exalt Floor Combi alerts

  • E1CTRLMax control (E-code lockout display)
  • E2CTRLMax control (E-code lockout display)
  • E3CTRLMax control (E-code lockout display)
  • E5CTRLMax control (E-code lockout display)
  • E8CTRLMax control (E-code lockout display)
  • E9CTRLMax control (E-code lockout display)
  • E13CTRLMax control (E-code lockout display)
  • E15CTRLMax control (E-code lockout display)
  • E16CTRLMax control (E-code lockout display)
  • E17CTRLMax control (E-code lockout display)
  • E18CTRLMax control (E-code lockout display)
  • E19CTRLMax control (E-code lockout display)
  • E21CTRLMax control (E-code lockout display)
  • E30CTRLMax control (E-code lockout display)
  • E31CTRLMax control (E-code lockout display)
  • E43CTRLMax control (E-code lockout display)
  • E44CTRLMax control (E-code lockout display)
  • E47CTRLMax control (E-code lockout display)
  • E80CTRLMax control (E-code lockout display)
  • E83CTRLMax control (E-code lockout display)
  • E87CTRLMax control (E-code lockout display)
  • E7CTRLMax control (E-code lockout display)
  • E12CTRLMax control (E-code lockout display)
  • E25CTRLMax control (E-code lockout display)
  • E32CTRLMax control (E-code lockout display)
  • E33CTRLMax control (E-code lockout display)
  • E34CTRLMax control (E-code lockout display)
  • E37CTRLMax control (E-code lockout display)
  • E45CTRLMax control (E-code lockout display)
  • E46CTRLMax control (E-code lockout display)
  • E76CTRLMax control (E-code lockout display)
  • E77CTRLMax control (E-code lockout display)
  • E78CTRLMax control (E-code lockout display)
  • E79CTRLMax control (E-code lockout display)
  • E81CTRLMax control (E-code lockout display)
  • E82CTRLMax control (E-code lockout display)
  • E89CTRLMax control (E-code lockout display)
  • E90CTRLMax control (E-code lockout display)
  • E91CTRLMax control (E-code lockout display)
  • E92CTRLMax control (E-code lockout display)
  • E93CTRLMax control (E-code lockout display)
  • E94CTRLMax control (E-code lockout display)
  • E95CTRLMax control (E-code lockout display)
  • E96CTRLMax control (E-code lockout display)
  • E97CTRLMax control (E-code lockout display)
  • E98CTRLMax control (E-code lockout display)
  • E99CTRLMax control (E-code lockout display)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Does the Exalt Floor Combi include a pump and separator?

Yes. The official page lists a pre-installed internal circulator and a Caleffi 548 series separator with air elimination, with water and gas connections available on the left or right side.

How much hot water can the Exalt Floor Combi produce?

4.0 GPM at a 70°F rise on the combi 155 and 5.3 GPM on the combi 199, with 3.7 / 4.9 GPM at 75°F and 3.5 / 4.6 GPM at 80°F, and a 0.5 GPM minimum flow rate.

What is the difference between the Exalt Floor and Exalt Floor Combi?

The heat-only Exalt Floor models (110, 155, 199) provide space heating only and pair with a separate DHW source, while the combi models (155, 199) add on-demand domestic hot water through a plate heat exchanger in the same floor-standing chassis.