Laars Heating Systems · FT Series Floor
Laars FTCF199N
The Laars FTCF199N is the combination FT Series Floor boiler: a floor-standing condensing combi printed at 199,000 BTU/h in Document 1505C with integrated domestic hot water and the FT floor combi code table.
Key figures
- Max input
- 199 MBH
- Max CSA output
- —
- AFUE
- —
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Laars FTCF199N in practice
The FTCF199N is the floor-standing combi of the FT line, printed at 199,000 BTU/h on the cover of its combination installation manual, Document 1505C, and producing domestic hot water in the same appliance as the space heating. Natural gas is the factory configuration with propane field-convertible.
Its Section 6.1 code table follows the FT floor combi set: two-digit codes from repeated flame-extinguishment through exhaust-gas temperature (94), including the DHW-side entries a combi carries, with Soft Lock and Hard Lock recovery per code. The combi's DHW demand is why the gas supply and vent route must be sized for the full 199,000 BTU/h firing rate.
Best suited to
- Homes wanting a floor-standing combi with integrated domestic hot water
- Heating and hot-water loads that both fit the single 199,000 BTU/h appliance
- Replacements where a floor boiler plus separate tank becomes one unit
Applicability and support
- Model number
- FTCF199N
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Laars Heating Systems. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Maximum input (as printed) | 199 MBH | Printed on the installation manual cover as the FTCF199N 199,000 BTU/h floor-standing combination model (Document 1505C). |
| Domestic hot water | ||
| Domestic hot water | Integrated — the combi version produces domestic hot water in the combination boiler | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Natural gas is the factory configuration; propane is field-convertible per the manual cover. |
| Error reporting | Two-digit numeric codes with Soft Lock and Hard Lock classes per Section 6.1 of the installation manual | |
Frequently asked questions
How does the FTCF199N differ from the FTHF199N?
Both are floor-standing FT models printed at 199,000 BTU/h, but the FTCF199N is the combination version with integrated domestic hot water, documented in Document 1505C rather than the heating-only Document 1510B.
Does the FTCF199N need a separate tank for hot water?
No — it is the combi floor model, so domestic hot water is produced by the combination boiler itself. The heating-only FTHF199N is the floor model that works with a separate tank or water heater.
Where do I find the FTCF199N error table?
Section 6.1 of the combination installation manual, Document 1505C, lists the two-digit codes with their Soft Lock or Hard Lock recovery for the FTCF199N.
Questions about the Laars FTCF199N?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Laars Heating Systems — official site · accessed September 7, 2026
- Laars — contact (Laars Canada, 9 Brigden Gate, Halton Hills, Ontario) · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.