New Yorker Boiler · GHE-II

New Yorker GHE-II GHE2-120B

The New Yorker GHE-II GHE2-120B is the mid-small size sharing the compact 16.3-inch-deep cabinet: 13.6–120 MBH heating input with 112 MBH DOE heating capacity and a 97 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

CurrentCanadian status unknown

Key figures

Max input
120 MBH
Max CSA output
AFUE
95 %
Min input
13.6 MBH
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

New Yorker GHE-II GHE2-120B in practice

The GHE-II GHE2-120B is a condensing, direct-vent gas heating boiler rated at 13.6–120 MBH input. Its row in the GHE-II data sheet prints 112 MBH DOE heating capacity, a 97 MBH net AHRI water rating (1.15 piping and pickup allowance) and 95.0% AFUE, with a 2" vent and air-intake connection, a 16.3"-deep cabinet and a listed weight of 76 lb.

The boiler is wall hung on a pre-installed bracket and wall-mount kit and uses the automatic no-touch combustion management control with built-in self diagnostics, warm-weather shutdown and sensor-less rate-based reset; a UL353 boiler flow safety switch, low gas pressure capability (2.5 in. wc natural gas / 8.0 in. wc LP) and a Grundfos 26-99 circulator are standard on heating-only models. Altitude capability extends to 10,100 feet on SKUs with the 'G00' suffix, and the LP conversion is a two-step field procedure at the gas valve and display with no kit required.

Boilers.ca documents this size at model level from the data sheet and links the published I&O manual. Gas, venting and electrical work belongs with a licensed contractor. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • 13.6-to-120 MBH residential heat-loss loads
  • Wall-hung installations with a 2-inch direct-vent route
  • Homes pairing the boiler with an indirect water heater

Applicability and support

Model number
GHE2-120B
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by New Yorker Boiler. Units are shown with every value; notes flag conflicting sources or missing figures.

New Yorker GHE-II GHE2-120B specifications
SpecificationValueNote
Input
Input, minimum13.6 MBHMinimum heating input per the GHE-II data sheet ratings table.
Input, maximum120 MBHMaximum heating input per the GHE-II data sheet ratings table; performance is shown for elevations to 2,000 ft with minimum vent length, and 'G00' SKUs cover altitudes to 10,100 ft.
Output
DOE heating capacity112 MBHDOE heating capacity per the GHE-II data sheet ratings table.
Net AHRI water rating97 MBHNet AHRI water rating per the GHE-II data sheet, based on a piping and pickup allowance of 1.15.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE per the GHE-II data sheet ratings table; the page headline is 95% AFUE.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
Vent and air intake2"2" vent and air-intake connection per the data sheet; horizontal and vertical two-pipe, concentric, low-profile and hybrid configurations are illustrated, plus a polypropylene chimney-chase option.
Physical and connections
Boiler weight76 lbBoiler weight per the GHE-II data sheet ratings table.
Boiler depth16.3"Boiler depth per the GHE-II data sheet dimension table; the model is wall hung on the supplied bracket.
Water connectionsPrimary/secondary header with 1-1/4" sweat connections (kit on heating-only models)The data sheet lists a primary/secondary manifold kit (P/N 111884-01) as an accessory for heating-only models.
Gas connection1/2" NPT gas connectionGas connection per the GHE-II data sheet dimension drawing; low gas pressure capability min 2.5 in. wc natural gas / 8.0 in. wc LP.
Operating limits and other
ControlAutomatic no-touch combustion management with built-in self diagnosticsControl provides warm-weather shutdown, sensor-less rate-based reset, two inputs (thermostat and DHW) and two-step LP conversion at the gas valve and display; UL353 boiler flow safety switch standard.
FuelNatural gas or LP gas (two-step conversion, no kit required)The data sheet describes simple two-step LP conversion with no kit purchase required.

Frequently asked questions

What are the GHE-II GHE2-120B's ratings?

13.6–120 MBH input, 112 MBH DOE heating capacity, a 97 MBH net AHRI water rating and 95.0% AFUE per the GHE-II data sheet.

How is the GHE-II GHE2-120B vented?

Direct vent, sealed combustion on a 2-inch vent and air-intake connection, with horizontal and vertical two-pipe, concentric, low-profile and hybrid configurations per the data sheet.

Questions about the New Yorker GHE-II GHE2-120B?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate