New Yorker Boiler GHE-II

The New Yorker GHE-II is the brand's 95% AFUE condensing gas heating boiler: four heating-only sizes GHE2-080 through GHE2-180 covering 8–80 to 20–180 MBH input with a 316L stainless-steel heat exchanger, automatic no-touch combustion setup, sensor-less rate-based reset and a 2-inch direct-vent connection.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
95% AFUE
Fuel
Natural gas / Propane
Venting
Direct vent, sealed combustion on a 2" vent and air-intake connection, with horizontal and vertical two-pipe, concentric, low-profile and hybrid configurations and a polypropylene chimney-chase option per the data sheet; the boiler flow safety switch is UL353 listed.
Models documented
4

All four heating-only rows print 95.0% AFUE in the GHE-II data sheet ratings table; the page headline is 95% AFUE.

About the GHE-II

The GHE-II is New Yorker's high-efficiency condensing gas boiler, published on the official site under Condensing Gas with the tagline 'Just hang and heat' and a 95% AFUE headline. The product page describes a 316L stainless-steel heat exchanger, direct-vent sealed combustion with a 2-inch vent and air-intake connection, a no-touch automatic combustion setup with no manual throttle or offset adjustments, three-side unobstructed service access, sensor-less rate-based temperature reset (no outdoor sensor required), a simple two-step LP conversion with no kits, low gas pressure capability, a pre-installed hanging bracket and wall-mount kit, and a 5-year parts warranty with a 12-year limited heat exchanger warranty. Altitude capability extends to 10,100 feet on SKUs with the 'G00' suffix.

The GHE-II data sheet prints the heating-only ratings rows documented at model level here: GHE2-080 (8–80 MBH input, 75 MBH DOE heating capacity, 65 MBH net AHRI, 2" vent, 71 lb, 16.3" deep), GHE2-120B (13.6–120 MBH, 112/97 MBH, 2", 76 lb, 16.3"), GHE2-150 (20–150 MBH, 141/123 MBH, 2", 103 lb, 20.4") and GHE2-180 (20–180 MBH, 169/147 MBH, 2", 103 lb, 20.4"). All four rows print 95.0% AFUE; performance is shown for elevations to 2,000 feet with minimum vent length, and 'G00' SKUs cover altitudes to 10,100 feet. The standard equipment list includes the automatic combustion management control with built-in self diagnostics, two inputs (thermostat and DHW), warm-weather shutdown, a boiler flow safety switch, a Grundfos 26-99 circulator on heating-only models, a low gas pressure capability of 2.5 in. wc natural gas / 8.0 in. wc LP, and a vent connection for CPVC/PVC and polypropylene.

Boilers.ca documents all four heating-only sizes at model level from the data sheet and links the published I&O manual; the combi models GHE2C-136B and GHE2C-200 are documented under the GHE-II Combi series page. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Highlights

  • Current New Yorker condensing gas heating boiler: GHE2-080, GHE2-120B, GHE2-150, GHE2-180
  • 95.0% AFUE on all four printed rows; 8–80 up to 20–180 MBH input
  • 316L stainless-steel heat exchanger; direct vent on a 2" connection
  • Automatic 'no-touch' combustion setup; sensor-less rate-based reset
  • Two-step LP conversion at the gas valve and display — no kit purchase
  • Altitude capability to 10,100 feet on 'G00' SKU suffix models
  • Model-level pages published on Boilers.ca; data sheet and I&O manual linked here

Five-year parts warranty with a 12-year limited heat exchanger warranty per the GHE-II data sheet; the New Yorker Limited Warranty document is published on the Tech & Lit page.

Models

GHE-II models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
8–80 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-080 is the smallest GHE-II heating size and the lowest minimum fire in the line: 8–80 MBH heating input with 75 MBH DOE heating capacity and a 65 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
13.6–120 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-120B is the mid-small size sharing the compact 16.3-inch-deep cabinet: 13.6–120 MBH heating input with 112 MBH DOE heating capacity and a 97 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-150 is the first of the deeper 20.4-inch cabinet sizes: 20–150 MBH heating input with 141 MBH DOE heating capacity and a 123 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–180 MBH
Output (max)
—
AFUE
95 %

The New Yorker GHE-II GHE2-180 is the largest heating-only GHE-II size: 20–180 MBH heating input with 169 MBH DOE heating capacity and a 147 MBH net AHRI water rating at 95.0% AFUE on the 316L stainless-steel condensing platform.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of New Yorker GHE-II GHE2-080 and New Yorker GHE-II GHE2-120B and New Yorker GHE-II GHE2-150 and New Yorker GHE-II GHE2-180
SpecificationNew Yorker GHE-II GHE2-080New Yorker GHE-II GHE2-120BNew Yorker GHE-II GHE2-150New Yorker GHE-II GHE2-180
Input, minimum8 MBH13.6 MBH20 MBH20 MBH
Input, maximum80 MBH120 MBH150 MBH180 MBH
output-max————
Efficiency (AFUE)95 %95 %95 %95 %
turndown————
vent-max-3————
vent-max-2————
Boiler weight71 lb76 lb103 lb103 lb

Read the full comparison: New Yorker GHE-II GHE2-080 vs GHE2-150 →

Read the full comparison: New Yorker GHE-II GHE2-080 vs GHE2-120B →

Read the full comparison: New Yorker GHE-II GHE2-120B vs GHE2-150 →

Read the full comparison: New Yorker GHE-II GHE2-150 vs GHE2-180 →

Error codes and alerts

GHE-II alerts

  • H01GHE-II control (H hold/warning and E lockout codes)
  • H02GHE-II control (H hold/warning and E lockout codes)
  • H04GHE-II control (H hold/warning and E lockout codes)
  • E04GHE-II control (H hold/warning and E lockout codes)
  • H05GHE-II control (H hold/warning and E lockout codes)
  • E05GHE-II control (H hold/warning and E lockout codes)
  • H06GHE-II control (H hold/warning and E lockout codes)
  • E06GHE-II control (H hold/warning and E lockout codes)
  • H07GHE-II control (H hold/warning and E lockout codes)
  • E07GHE-II control (H hold/warning and E lockout codes)
  • H08GHE-II control (H hold/warning and E lockout codes)
  • H09GHE-II control (H hold/warning and E lockout codes)
  • E09GHE-II control (H hold/warning and E lockout codes)
  • H11GHE-II control (H hold/warning and E lockout codes)
  • E11GHE-II control (H hold/warning and E lockout codes)
  • H12GHE-II control (H hold/warning and E lockout codes)
  • H13GHE-II control (H hold/warning and E lockout codes)
  • H14GHE-II control (H hold/warning and E lockout codes)
  • E15GHE-II control (H hold/warning and E lockout codes)
  • H16GHE-II control (H hold/warning and E lockout codes)
  • E16GHE-II control (H hold/warning and E lockout codes)
  • H17GHE-II control (H hold/warning and E lockout codes)
  • E17GHE-II control (H hold/warning and E lockout codes)
  • H18GHE-II control (H hold/warning and E lockout codes)
  • E18GHE-II control (H hold/warning and E lockout codes)
  • E19GHE-II control (H hold/warning and E lockout codes)
  • H20GHE-II control (H hold/warning and E lockout codes)
  • E20GHE-II control (H hold/warning and E lockout codes)
  • H21GHE-II control (H hold/warning and E lockout codes)
  • E21GHE-II control (H hold/warning and E lockout codes)
  • H22GHE-II control (H hold/warning and E lockout codes)
  • E22GHE-II control (H hold/warning and E lockout codes)
  • H23GHE-II control (H hold/warning and E lockout codes)
  • E23GHE-II control (H hold/warning and E lockout codes)
  • H24GHE-II control (H hold/warning and E lockout codes)
  • E24GHE-II control (H hold/warning and E lockout codes)
  • H25GHE-II control (H hold/warning and E lockout codes)
  • E25GHE-II control (H hold/warning and E lockout codes)
  • H26GHE-II control (H hold/warning and E lockout codes)
  • E26GHE-II control (H hold/warning and E lockout codes)
  • H27GHE-II control (H hold/warning and E lockout codes)
  • H28GHE-II control (H hold/warning and E lockout codes)
  • E29GHE-II control (H hold/warning and E lockout codes)
  • H30GHE-II control (H hold/warning and E lockout codes)
  • H31GHE-II control (H hold/warning and E lockout codes)
  • H32GHE-II control (H hold/warning and E lockout codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the New Yorker GHE-II available in Canada?

No official Canadian-sales statement was found on the official pages reviewed on September 9, 2026, so canadianStatus is recorded 'unknown'. Confirm supply through a licensed distributor.

What sizes does the GHE-II heating boiler come in?

Four heating-only sizes: GHE2-080, GHE2-120B, GHE2-150 and GHE2-180, covering 8–80, 13.6–120, 20–150 and 20–180 MBH input at 95.0% AFUE per the GHE-II data sheet.

Does the GHE-II need an outdoor sensor?

No — the data sheet describes sensor-less, rate-based reset, and the page lists 'No outdoor sensor required' among the design features.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate