Peerless Cast 92 COMBUSTION AIR DAMPER FAILURE — Combustion Air Damper Failure

COMBUSTION AIR DAMPER FAILURE

Needs attentionPeerless Cast 92 condensing boilers (HeatNet control, manual C928000 R1)

Combustion air damper failure. Display shows combustion air damper failure: disable the damper in the AUX FUNCTIONS menu if not used; check the prove switch closes and is controlled by the programmed output relay; jumper USER INTRLK if there is no proving switch; check the sensor TYPE in the SENSORS menu is set to ON/OFF (Table 12.1, p. 95). The table classifies it as blocking.

Applies to

This venting or air-supply fault code is displayed by the HeatNet control on Cast 92 models (92-2, 92-4), as documented in CAST 92 Gas Boilers Installation, Operation & Maintenance Manual, C928000 R1 (11/13), Tables 11.1 and 12.1 (C928000 R1). Codes can differ between controller generations, so always check the manual that matches your unit.

Controller: HeatNet control. Source manual: C928000 R1.

Why a code is not a diagnosis

A venting or air-supply code points at the combustion-air path: a blocked terminal, a restricted flue, a failed fan, or a condensate restriction. It does not say which, and running an appliance with a blocked flue is unsafe.

Safe things to observe

  • If a carbon-monoxide alarm sounds anywhere in the building, leave immediately and call 911 from outside.
  • From a safe distance, check that the vent terminal and combustion-air inlet are not blocked.
  • Do not run the appliance while a blockage is suspected.

Do not

  • Do not put anything into the vent or air-intake openings.
  • Do not remove or modify vent pipe.

How professional service helps

  1. A technician inspects the full vent and combustion-air path, clears blockages and checks the fan.
  2. Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Parts and service

Parts commonly involved

These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.

Service for this alert

  • Gas Boiler Repair

    Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…

Every boiler part explained — what it does, how it fails and what a technician checks.

Documented for Peerless Boilers Cast 92.

Frequently asked questions

Can I clear this code myself?

Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.

Boiler locked out? Call with the alert text ready.

The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate