Skip to content
Boilers.caby ROMA Heating & Cooling

Peerless Boilers · Cast 92

Peerless Cast 92-2

The Peerless Cast 92-2 is the legacy residential gas-fired condensing cast-iron boiler: a single-model line with a 40–199 MBH CSA input range whose 199 MBH rating row prints 184 MBH output and a 148 MBH net rating at 90% AFUE (ENERGY STAR certified), sealed-combustion direct vent with a 3" flue, 4.75 gallons of water and a HeatNet text-display control.

DiscontinuedCanadian status unknown

Key figures

Max input
—
Max CSA output
—
AFUE
90 %
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Peerless Cast 92-2 in practice

The Cast 92-2 is the residential member of Peerless' legacy Cast 92 condensing cast-iron family, published under 'Out of Circulation – Gas Boilers' on the official site. The page describes a 90% efficient, ENERGY STAR certified condensing boiler whose cast-iron heat exchanger 'retains heat longer than other types of heat exchangers', with low CO2 and NOx emissions, quiet operation and a compact space-saving design positioned for replacing older, larger, less-efficient cast-iron boilers.

The rating table prints 199 MBtu/hr input, 184 MBH output, a 148 MBtu/hr net rating and 90% AFUE, with a 2"–14" W.C. gas pressure range, 2–36 GPM flow (2 GPM at 100% input), 20–100°F temperature rise, 0–100 equivalent feet of vent and air-inlet piping, 4.75 gallons of water, a 3" flue, 2.75 A current FLA and 5.3 boiler horsepower. Combustion is direct spark and venting is sealed-combustion direct vent.

The Cast 92-2 shares the HeatNet text-display control with the Cast 92-4 (cascade-capable, Modbus RS485 per the I&O manual). The official site groups the product under 'Out of Circulation', so productStatus is 'discontinued'; Boilers.ca documents the printed model row from the product page and the C928000 R1 I&O manual. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Best suited to

  • Owners documenting an installed Cast 92-2 against the official rating table
  • Service planning for the HeatNet control and sealed-combustion venting
  • Legacy replacement research in the 199-MBH-input condensing class

Applicability and support

Model number
92-2
Canadian availability
unknown
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Peerless Boilers. Units are shown with every value; notes flag conflicting sources or missing figures.

Peerless Cast 92-2 specifications
SpecificationValueNote
Input
Input40–199 MBHCSA input range 40,000–199,000 Btuh per the Cast 92 catalog; the product-page rating table prints the 199 MBH maximum row.
Output
Output184 MBHOutput per the rating table on the Cast 92-2 product page; the Cast 92 catalog's specification table prints 170 MBH for the same row.
Net rating148 MBHNet rating per the rating table on the Cast 92-2 product page.
Efficiency
Efficiency (AFUE)90 %90% AFUE; the product page describes the Cast 92-2 as ENERGY STAR certified and 90% efficient.
Domestic hot water
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Venting and air
VentingSealed combustion, direct vent — 3" flue3" flue diameter; up to 100 equivalent feet of vent and air inlet length per the rating table.
Physical and connections
Water volume4.75 galWater volume per the rating table on the Cast 92-2 product page.
Electrical
Electrical120VAC/60Hz/1PH, 2.75 AVoltage and current FLA per the rating table on the Cast 92-2 product page.
Operating limits and other
Gas pressure (W.C.)2"–14"Gas pressure range per the rating table on the Cast 92-2 product page.
Flow2–36 GPMFlow range per the rating table; 2 GPM marked at 100% input.
Boiler H.P.5.3Boiler horsepower per the rating table on the Cast 92-2 product page.
IgnitionDirect sparkDirect-spark combustion per the product page product details; HeatNet text-display control.

Frequently asked questions

What are the Cast 92-2's ratings?

199 MBtu/hr input, 184 MBH output, a 148 MBtu/hr net rating and 90% AFUE per the rating table on the product page; the page describes the model as ENERGY STAR certified.

Does the Cast 92-2 need a chimney?

No — it is a sealed-combustion, direct-vent condensing boiler with a 3" flue and up to 100 equivalent feet of vent and air-inlet piping.

Is the Cast 92-2 still sold?

No — the official site groups the Cast 92-2 under 'Out of Circulation' (verified September 9, 2026); the record documents the installed equipment and its I&O manual.

Questions about the Peerless Cast 92-2?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate