Skip to content
Boilers.caby ROMA Heating & Cooling

Pennco · Series

Pennco 15B-K

The Pennco 15B-K is a cast-iron, chimney-vented gas water boiler rated 84% AFUE and sold in seven sizes from 15B-060K (59 MBH input) to 15B-235K (235 MBH), with a low-profile draft diverter hood, removable burner tray and internal or Resideo gas-valve configurations.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
84% AFUE
Fuel
The sell sheet states 'For Natural Gas Or Propane' and describes a removable burner tray for quick access to change orifices (LP gas, high altitude); no separate LP SKUs are printed.
Venting
Chimney vented with a low-profile draft diverter hood that the sell sheet states reduces installation height by up to 30 inches compared with taller draft hoods; flue collar diameter steps from 4" (15B-060K) to 7" (15B-175K and larger).
Models documented
7

All seven 15B-K rows print 84% AFUE in the sell sheet ratings table.

About the 15B-K

The Pennco 15B-K is a gas-fired cast-iron water boiler published on the official site under Boilers – Gas with the size list '59, 90.8, 120, 149, 175, 205, 235 MBH'. The sell sheet describes an 84% AFUE boiler with a dependable cast-iron heat exchanger with dry-leg end sections, each heat exchanger water- and pressure-tested before assembly; an internal operating control with a digital display; a low-profile draft diverter hood that reduces installation height by up to 30 inches; and a removable burner tray for easy cleaning and quick access to change orifices for LP gas and high altitude. The model is offered for natural gas or propane.

The sell sheet ratings table prints the seven documented sizes: 15B-060K (59 MBH input, 50 MBH heating capacity, 43 MBH net AHRI, 84% AFUE, 4" flue, 13-3/8" wide, 215 lb), 15B-095K (90.8/76.3/66 MBH, 5", 250 lb), 15B-120K (120/101/88 MBH, 6", 295 lb), 15B-150K (149/125/109 MBH, 6", 335 lb), 15B-175K (175/147/128 MBH, 7", 385 lb), 15B-205K (205/172/150 MBH, 7", 420 lb) and 15B-235K (235/197/171 MBH, 7", 465 lb). Input ratings are for sea level to 2,000 feet and reduce four percent per 1,000 feet above that, and net AHRI water ratings use a 1.15 piping and pickup allowance. All models share a 32-1/8-inch height with depths of 27-1/4 inches (15B-205K/235K 27-3/4 inches).

Two control configurations are documented on the official documents page: an internal gas valve version (IOM Rev. C and User Manual Rev. E) and a Resideo-control version (IOM Rev. D). Boilers.ca documents all seven sizes at model level from the sell sheet and links the published manuals. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Highlights

  • Current Pennco gas-fired cast-iron water boiler: 15B-060K to 15B-235K (seven sizes)
  • 84% AFUE on every printed row; 59–235 MBH input
  • Heating capacity 50–197 MBH; net AHRI water 43–171 MBH at 1.15 allowance
  • Low-profile draft diverter hood reduces installation height by up to 30 inches
  • Removable burner tray for cleaning and orifice changes (LP gas, high altitude)
  • Internal gas valve and Resideo-control configurations documented
  • Model-level pages published on Boilers.ca; sell sheet and IOM manuals linked here

Pennco Cast Iron Consolidated Boiler Warranty Rev. C is published on the official documents page.

Models

15B-K models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco 15B-060K is the smallest 15B-K size with a 4-inch flue: 59 MBH input with 50 MBH heating capacity and a 43 MBH net AHRI water rating at 84% AFUE, chimney vented with a 4" flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco 15B-095K is the second size, stepping to a 5-inch flue: 90.8 MBH input with 76.3 MBH heating capacity and a 66 MBH net AHRI water rating at 84% AFUE, chimney vented with a 5" flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco 15B-120K is the mid-size 15B-K with a 6-inch flue: 120 MBH input with 101 MBH heating capacity and a 88 MBH net AHRI water rating at 84% AFUE, chimney vented with a 6" flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco 15B-150K is the fourth size, sharing the 6-inch flue: 149 MBH input with 125 MBH heating capacity and a 109 MBH net AHRI water rating at 84% AFUE, chimney vented with a 6" flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco 15B-175K is the first size with a 7-inch flue: 175 MBH input with 147 MBH heating capacity and a 128 MBH net AHRI water rating at 84% AFUE, chimney vented with a 7" flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco 15B-205K is the second-largest 15B-K size: 205 MBH input with 172 MBH heating capacity and a 150 MBH net AHRI water rating at 84% AFUE, chimney vented with a 7" flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco 15B-235K is the largest 15B-K size: 235 MBH input with 197 MBH heating capacity and a 171 MBH net AHRI water rating at 84% AFUE, chimney vented with a 7" flue.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Pennco 15B-060K and Pennco 15B-095K and Pennco 15B-120K and Pennco 15B-150K and Pennco 15B-175K and Pennco 15B-205K and Pennco 15B-235K
SpecificationPennco 15B-060KPennco 15B-095KPennco 15B-120KPennco 15B-150KPennco 15B-175KPennco 15B-205KPennco 15B-235K
input-min
Input59 MBH90.8 MBH120 MBH149 MBH175 MBH205 MBH235 MBH
output-max
Efficiency (AFUE)84 %84 %84 %84 %84 %84 %84 %
turndown
vent-max-3
vent-max-2
Approx. shipping weight215 lb250 lb295 lb335 lb385 lb420 lb465 lb

Read the full comparison: Pennco 15B-060K vs 15B-120K

Read the full comparison: Pennco 15B-060K vs Pennco 15B-095K

Read the full comparison: Pennco 15B-095K vs Pennco 15B-120K

Read the full comparison: Pennco 15B-120K vs Pennco 15B-150K

Error codes and alerts

15B-K alerts

  • 4Resideo integrated boiler control (numeric error codes)
  • 6Resideo integrated boiler control (numeric error codes)
  • 18Resideo integrated boiler control (numeric error codes)
  • 23Resideo integrated boiler control (numeric error codes)
  • 24Resideo integrated boiler control (numeric error codes)
  • 32Resideo integrated boiler control (numeric error codes)
  • 55Resideo integrated boiler control (numeric error codes)
  • 56Resideo integrated boiler control (numeric error codes)
  • 57Resideo integrated boiler control (numeric error codes)
  • 58Resideo integrated boiler control (numeric error codes)
  • 59Resideo integrated boiler control (numeric error codes)
  • 60Resideo integrated boiler control (numeric error codes)
  • 61Resideo integrated boiler control (numeric error codes)
  • 62Resideo integrated boiler control (numeric error codes)
  • 63Resideo integrated boiler control (numeric error codes)
  • 64Resideo integrated boiler control (numeric error codes)
  • 65Resideo integrated boiler control (numeric error codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the Pennco 15B-K come in?

Seven sizes: 15B-060K through 15B-235K, covering 59, 90.8, 120, 149, 175, 205 and 235 MBH input at 84% AFUE per the sell sheet.

Is the 15B-K available for propane?

Yes — the sell sheet states 'For Natural Gas Or Propane' and describes the removable burner tray allowing quick orifice changes for LP gas and high altitude.

Is the 15B-K available in Canada?

No official Canadian-sales statement was found on penncoboilers.com when reviewed on September 9, 2026, so canadianStatus is recorded 'unknown'.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate