Pennco · Series

Pennco FSB Series

The Pennco FSB Series is a cast-iron gas water boiler sold in five sizes from FSB-2 (42.5 MBH input) to FSB-6 (187.5 MBH) at 84–84.4% AFUE, with cast-iron push nipples, a control that delays burner starting until residual heat is transferred, and chimney or sidewall venting options.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
non-condensing
Efficiency
84.4% AFUE
Fuel
The sell sheet lists 'Natural Gas or Propane' under optional equipment.
Venting
Chimney or sidewall venting: the ratings table lists a 4" chimney connection for all sizes and a 3" sidewall option except the FSB-6, which lists 4" sidewall. The sell sheet notes a thimble option and references the IOM for approved venting materials and equivalent lengths.
Models documented
5

The ratings table prints 84.4% AFUE on the FSB-2 and 84% on FSB-3 through FSB-6.

About the FSB Series

The FSB Series is Pennco's gas-fired cast-iron water boiler, published on the official site under Boilers – Gas with the size list '42.5, 75, 112.5, 150, 187.5 MBH'. The sell sheet describes a dependable cast-iron heat exchanger with cast-iron push nipples — the sections and push nipples expand at the same rate when heated, maintaining a water-tight seal over time without gaskets — and a control that monitors water temperature and delays the burner start until residual heat has been transferred, maximizing efficiency by firing only when needed. Optional equipment includes natural gas or propane operation, a Fill-Trol and a thimble; the boiler is design certified for installation on a noncombustible floor and tested for 50 PSI ASME working pressure.

The sell sheet ratings table prints five sizes: FSB-2 (42.5 MBH input, 36 MBH heating capacity, 31 MBH net water rating, 84.4% AFUE, 4" chimney / 3" sidewall, 11" wide, 225 lb), FSB-3 (75/63/55 MBH, 84%, 4"/3", 265 lb), FSB-4 (112.5/95/82 MBH, 84%, 4"/3", 322 lb), FSB-5 (150/127/109 MBH, 84%, 4"/3", 370 lb) and FSB-6 (187.5/158/135 MBH, 84%, 4"/4", 431 lb). Heating capacity and AFUE are based on DOE test procedures and the net water rating uses a 1.15 piping and pickup allowance. All sizes share a 29-inch height and 23-1/4-inch depth, with a 1/2-inch gas inlet and 1-1/4-inch supply and return tappings.

Boilers.ca documents all five sizes at model level from the sell sheet and links the published Series 3 and Series 4 IOMs. No official Canadian-sales statement was found, so canadianStatus stays 'unknown'.

Highlights

  • Current Pennco gas-fired cast-iron water boiler: FSB-2 to FSB-6 (five sizes)
  • 84.4% AFUE on FSB-2, 84% on FSB-3 through FSB-6; 42.5–187.5 MBH input
  • Heating capacity 36–158 MBH; net water rating 31–135 MBH at 1.15 allowance
  • Cast-iron push nipples — no gaskets in the section assembly
  • Control delays burner start until residual heat is transferred
  • Chimney (4") or sidewall (3"–4") venting options per the ratings table
  • Model-level pages published on Boilers.ca; sell sheet and IOMs linked here

Pennco Cast Iron Consolidated Boiler Warranty Rev. C is published on the official documents page.

Models

FSB Series models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
Output (max)
AFUE
84.4 %

The Pennco FSB-2 is the smallest FSB size and the only 84.4% AFUE row: 42.5 MBH input with 36 MBH heating capacity and a 31 MBH net water rating at 84.4% AFUE, vented through a 4" chimney or 3" sidewall connection.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco FSB-3 is the second FSB size: 75 MBH input with 63 MBH heating capacity and a 55 MBH net water rating at 84% AFUE, vented through a 4" chimney or 3" sidewall connection.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco FSB-4 is the mid-size FSB: 112.5 MBH input with 95 MBH heating capacity and a 82 MBH net water rating at 84% AFUE, vented through a 4" chimney or 3" sidewall connection.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco FSB-5 is the second-largest FSB size: 150 MBH input with 127 MBH heating capacity and a 109 MBH net water rating at 84% AFUE, vented through a 4" chimney or 3" sidewall connection.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Pennco FSB-6 is the largest FSB size and the only row listing a 4-inch sidewall vent: 187.5 MBH input with 158 MBH heating capacity and a 135 MBH net water rating at 84% AFUE, vented through a 4" chimney or 4" sidewall connection.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Pennco FSB-2 and Pennco FSB-3 and Pennco FSB-4 and Pennco FSB-5 and Pennco FSB-6
SpecificationPennco FSB-2Pennco FSB-3Pennco FSB-4Pennco FSB-5Pennco FSB-6
input-min
Input42.5 MBH75 MBH112.5 MBH150 MBH187.5 MBH
output-max
Efficiency (AFUE)84.4 %84 %84 %84 %84 %
turndown
vent-max-3
vent-max-2
Approx. shipping weight225 lb265 lb322 lb370 lb431 lb

Read the full comparison: Pennco FSB-2 vs FSB-4

Read the full comparison: Pennco FSB-2 vs Pennco FSB-3

Read the full comparison: Pennco FSB-3 vs Pennco FSB-4

Read the full comparison: Pennco FSB-4 vs Pennco FSB-5

Error codes and alerts

FSB Series alerts

  • 2Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 4Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 6Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 18Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 23Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 24Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 29Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 32Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 57Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 58Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 59Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 60Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 61Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 62Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 63Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 64Integrated boiler control (Honeywell 4200 series, numeric error codes)
  • 65Integrated boiler control (Honeywell 4200 series, numeric error codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What sizes does the Pennco FSB Series come in?

Five sizes: FSB-2 through FSB-6, covering 42.5, 75, 112.5, 150 and 187.5 MBH input at 84.4% (FSB-2) or 84% AFUE per the sell sheet.

Can the FSB Series be sidewall vented?

The ratings table lists a 4-inch chimney connection for all sizes and a 3-inch sidewall option except the FSB-6, which lists 4-inch sidewall; a thimble is an optional accessory and the IOM covers approved venting materials.

What makes the FSB different from other cast-iron boilers?

The sell sheet highlights cast-iron push nipples — sections and push nipples expand at the same rate, maintaining a water-tight seal without gaskets — and a control that delays the burner start until residual heat has been transferred.