Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Series

Viessmann Vitodens 100-W (legacy B1HA / B1KA and earlier)

This hub documents the earlier generations of the Vitodens 100-W sold in Canada — the B1HA/B1KA series and, before them, the WB1A and WB1B boilers — whose manuals live in Viessmann Canada's Historic manuals. Seven model records cover the printed rating tables: B1HA 26/94, B1HA 35/125, B1KA 35/125, WB1A 8-24, WB1A 8-30, WB1B 26 and WB1B 35.

discontinuedhistoricalNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
95% AFUE
Fuel
Natural gas / Propane
Venting
Unknown
Models documented
7
Warranty
Not verified

Legacy generation; figures per Viessmann historic documentation.

About the Vitodens 100-W (legacy B1HA / B1KA and earlier)

Earlier generations of the Vitodens 100-W — the B1HA heating-only series and B1KA combi, and before them the WB1A and WB1B boilers — are no longer sold in Canada, but Viessmann Canada keeps their installation and service instructions, technical data manuals and repair sheets under its Historic manuals downloads. The B1HA/B1KA generation is also kept in the current manuals library, including a technical data manual revised 04/2025. An owner of one of these units can still pull the documents that match the generation shown on the rating plate.

The printed rating tables documented on Boilers.ca cover seven models. B1HA 26/94 and B1HA 35/125 are heating-only wall-hung condensing boilers at 95.0% AFUE with 21-94 and 21-125 MBH natural-gas input; B1KA 35/125 adds on-demand domestic hot water through a plate heat exchanger at the same 95.0% AFUE. The earlier WB1A 8-24 and 8-30 print 95.1% AFUE at 29-80 and 29-100 MBH, and the WB1B 26 and 35 print 94.0% AFUE at 37-91 and 37-118 MBH on natural gas or propane.

Fault codes on the older controls are not interchangeable with the current series: the current 100-W B1HE/B1KE generation lists F.xx codes documented on Boilers.ca against manual 6167 818 - 22, while a WB1A, WB1B or B1HA unit shows the codes defined in its own manual generation. Note the exact code and compare it with the unit's own documentation before calling for service. Viessmann Canada's heat-exchanger replacement safety notice names only the Vitodens 200-W B2HB and 222-F B2TB series, so it does not list 100-W models.

Highlights

  • Seven model records: B1HA 26/94, B1HA 35/125, B1KA 35/125, WB1A 8-24, WB1A 8-30, WB1B 26 and WB1B 35
  • B1HA/B1KA generation: 21 to 125 MBH input at 95.0% AFUE; B1KA adds on-demand DHW
  • WB1A: 29-80 and 29-100 MBH at 95.1% AFUE; WB1B: 37-91 and 37-118 MBH at 94.0% AFUE
  • Installation, service and technical data documents under Viessmann Canada's Historic manuals
  • Fault codes differ from the current B1HE F.xx listings — check the unit's own manual generation
  • Not covered by the Vitodens 200/222 heat-exchanger replacement safety notice

Models

Vitodens 100-W (legacy B1HA / B1KA and earlier) models

One canonical page per model with input, output and efficiency kept separate.

DiscontinuedHistorically in Canada
Input
21–94 MBH
Output (max)
—
AFUE
95 %

The Vitodens 100-W B1HA 26, 94 is the smaller heating-only model of the B1HA/B1KA generation: 21 to 94 MBH natural gas input at 95.0% AFUE in a 79.4 lb (36 kg) wall-hung boiler.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
21–125 MBH
Output (max)
—
AFUE
95 %

The Vitodens 100-W B1KA 35, 125 is the combi model of the B1HA/B1KA generation: 21 to 125 MBH heating input at 95.0% AFUE plus on-demand DHW at up to 149 MBH input and a 3.5 USG/min continuous draw at a 77°F rise.

Natural gasPropaneCombi

Compare models in this series

Comparison of Viessmann Vitodens 100-W B1HA 26, 94 and Viessmann Vitodens 100-W B1HA 35, 125 and Viessmann Vitodens 100-W B1KA 35, 125 and Viessmann Vitodens 100-W WB1A 8-24 and Viessmann Vitodens 100-W WB1A 8-30 and Viessmann Vitodens 100-W WB1B 26 and Viessmann Vitodens 100-W WB1B 35
SpecificationViessmann Vitodens 100-W B1HA 26, 94Viessmann Vitodens 100-W B1HA 35, 125Viessmann Vitodens 100-W B1KA 35, 125Viessmann Vitodens 100-W WB1A 8-24Viessmann Vitodens 100-W WB1A 8-30Viessmann Vitodens 100-W WB1B 26Viessmann Vitodens 100-W WB1B 35
CSA input, minimum (natural gas)21 MBH21 MBH21 MBH29 MBH29 MBH37 MBH37 MBH
CSA input, maximum (natural gas)94 MBH125 MBH125 MBH80 MBH100 MBH91 MBH118 MBH
output-max———————
Efficiency (AFUE)95 %95 %95 %95.1 %95.1 %94 %94 %
turndown———————
vent-max-3———————
vent-max-2———————
Weight79.4 lb79.4 lb90 lb95 lb95 lb78 lb78 lb

Read the full comparison: Viessmann Vitodens 100-W B1HA 26, 94 vs B1HA 35, 125 →

Read the full comparison: Viessmann Vitodens 100-W B1HA 35, 125 vs B1KA 35, 125 →

Read the full comparison: Viessmann Vitodens 100-W WB1A 8-24 vs WB1A 8-30 →

Read the full comparison: Viessmann Vitodens 100-W WB1B 26 vs WB1B 35 →

Error codes and alerts

Vitodens 100-W (legacy B1HA / B1KA and earlier) alerts

No alerts documented for this series yet.

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

My older Vitodens 100-W shows a fault code — which manual applies?

Codes on WB1A/WB1B and B1HA/B1KA units are defined in that generation's own instructions under Viessmann Canada's Historic manuals, not in the current B1HE documents. Match any code to the unit's generation before acting on it.

Does the Viessmann heat exchanger notice affect the Vitodens 100-W?

The notice names only Vitodens 200-W B2HB and 222-F B2TB units, so it does not apply to 100-W models. Viessmann's serial number locator can still confirm the status of any individual boiler.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate