Viessmann · Vitodens 200-W (B2HB)

Viessmann Vitodens 200-W B2HB 35, 125

The Vitodens 200-W B2HB 35, 125 is the largest model of the B2HB compact chassis: 19 to 125 MBH natural gas input (31 to 125 MBH propane) at 95.0% AFUE with a 102 MBH Net AHRI rating.

DiscontinuedHistorically in Canada

Key figures

Max input
125 MBH
Max CSA output
AFUE
95 %
Min input
19 MBH
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitodens 200-W B2HB 35, 125 in practice

The B2HB 35, 125 closes out the B2HB small chassis at 125 MBH: printed natural gas input 19-125 MBH (5.5-37 kW), propane 31-125 MBH (9-37 kW), output 18-117 MBH (5-34 kW) and a 102 MBH Net AHRI rating at 95.0% AFUE.

It keeps the 110 lb (50 kg), 1.02 USG and 45 psig figures of the 19, 68 and 26, 94, and like them it must not be common-vented with any other appliance. The B2HB 35 is also one of the three models covered by Viessmann Canada's heat-exchanger replacement safety notice for units built September 1, 2014 to April 25, 2017.

Best suited to

  • Owners of existing B2HB 35/125 units verifying the safety notice
  • Residential loads whose heat-loss calculation lands between 94 and 125 MBH
  • Documentation reference for the last size in the B2HB compact chassis

Applicability and support

Model number
B2HB 35, 125
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitodens 200-W B2HB 35, 125 specifications
SpecificationValueNote
Input
CSA input, minimum (natural gas)19 MBH5.5 kW, per the technical data manual
CSA input, maximum (natural gas)125 MBH37 kW, per the technical data manual
CSA input (liquid propane)31-125 MBHPrinted LPG range; minimums are higher than natural gas on the 26/94 and larger sizes.
Output
CSA output / DOE heating capacity (natural gas)18-117 MBH5-34 kW, based on 140°F / 120°F supply/return
Net AHRI rating102 MBHBased on piping and pick-up allowance of 1.15.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE on all B2HB sizes per the technical data manual; up to 98% at full modulation.
Physical and connections
Weight110 lb50 kg
Width17.75 in450 mm
Depth15.7 in400 mm
Height41 in1040 mm
Operating limits and other
FuelNatural gas or liquid propaneAs printed in the technical data manual's CSA input rows.
Boiler water content1.02 USG
Maximum operating pressure45 psigAt 210°F (99°C).

Frequently asked questions

What is the firing range of the B2HB 35, 125?

19-125 MBH (5.5-37 kW) natural gas input and 31-125 MBH (9-37 kW) propane input, with 18-117 MBH output at 95.0% AFUE and a 102 MBH Net AHRI rating.

Is the B2HB 35 in the safety notice?

Yes — B2HB models 19, 26 and 35 manufactured between September 1, 2014 and April 25, 2017 are covered by Viessmann Canada's heat-exchanger replacement notice. Verify the serial number on the recall page.

What replaced the B2HB 35, 125?

The current Vitodens 200-W B2HE line; the B2HE-120 and B2HE-150 cover similar loads with the newer control platform. The B2HE models are not part of the B2HB safety notice.

Questions about the Viessmann Vitodens 200-W B2HB 35, 125?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.